5. 
Hardware Commands 
5.1. 
 Turning ON the GE865 
To turn on the GE865 the pad ON# must be tied low for at least 1 second and then released. 
 
When the power supply voltage is lower than 3.4V the pad ON# must be tied low at least 5 
seconds. 
 
The maximum current that can be drained from the ON# pad is 0,1 mA. 
A simple circuit to do it is: 
 
 
 
NOTE: 
Don't use any pull up resistor on the ON# line, it is internally pulled up. Using pull up resistor 
may bring to latch up problems on the GE865 power regulator and improper power on/off of the 
module. The line ON# must be connected only in open collector configuration. 
NOTE: 
In this document all the lines that are inverted, hence have active low signals are labelled with a 
name that ends with”#" or with a bar over the name. 
TIP: 
To check if the device has powered on, the hardware line PWRMON should be monitored. After 
900ms the line raised up the device could be considered powered on. 
NOTE: 
It is mandatory to avoid sending data to the serial ports during the first 200mS of the module 
start-up.