5.3. 
Resetting the GE865 
5.3.1. 
Hardware Unconditional restart  
WARNING
The hardware unconditional Restart must not be used during normal operation of the device 
since it does not detach the device from the network. It shall be kept as an emergency exit 
procedure to be done in the rare case that the device gets stacked waiting for some network or 
SIM responses. 
 
To unconditionally reboot the GE865, the pad RESET# must be tied low for at least 200 
milliseconds and then released. 
The maximum current that can be drained from the RESET# pad is 0,15 mA. 
 
NOTE:  
Do not use any pull up resistor on the RESET* line nor any totem pole digital output. Using pull 
up resistor may bring to latch up problems on the GE865 power regulator and improper 
functioning of the module. The line RESET* must be connected only in open collector 
configuration. 
TIP: 
The unconditional hardware restart must always be implemented on the boards and the software 
must use it as an emergency exit procedure. 
 
A simple circuit to do it is: