3Si Security Systems Inc. GT83000A Benutzerhandbuch

Seite von 77
 
 
 
 
 
GE865 Hardware User Guide 
1vv0300799 Rev.15– 2012-04-23   
  
  
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved 
 
page 39 of 77 
 
7.3.2. 
Transmission line measurements 
 
HP8753E VNA (Full-2-port calibration) has been used in this measurement session. A calibrated 
coaxial cable has been soldered at the pad corresponding to GE865 RF output; a SMA connector 
has been soldered to the board in order to characterize the losses of the transmission line 
including the connector itself. During Return Loss / impedance measurements, the transmission 
line has been terminated to 50 
Ω load. 
 
 
 
 
 
 
Return Loss plot of line under test is shown below: