3Si Security Systems Inc. GT83000A Benutzerhandbuch

Seite von 77
 
 
 
 
 
GE865 Hardware User Guide 
1vv0300799 Rev.15– 2012-04-23   
  
  
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved 
 
page 46 of 77 
 
9.2. 
RS232 level translation 
In order to interface the  GE865  with a PC com port or a RS232 (EIA/TIA-232) application a 
level translator is required. This level translator must: 
• 
invert the electrical signal in both directions; 
• 
change the level from 0/2.8V to +15/-15V . 
Actually, the RS232 UART 16450, 16550, 16650 & 16750 chipsets accept signals with lower 
levels on the RS232 side (EIA/TIA-562), allowing a lower voltage-multiplying ratio on the level 
translator. Note that the negative signal voltage must be less than 0V and hence some sort of 
level translation is always required.  
The simplest way to translate the levels and invert the signal is by using a single chip level 
translator. There are a multitude of them, differing in the number of drivers and receivers and in 
the levels (be sure to get a true RS232 level translator not a RS485 or other standards). 
By convention the driver is the level translator from the 0-2.8V UART to the RS232 level. The 
receiver is the translator from the RS232 level to 0-2.8V UART. 
In order to translate the whole set of control lines of the UART you will need: 
•  5 drivers 
•  3 receivers 
 
 
NOTE: 
The digital input lines working at 2.8V CMOS have an absolute maximum input voltage of 
3.0V; therefore the level translator IC shall not be powered by the +3.8V supply of the module. 
Instead, it must be powered from a +2.7V / +2.9V (dedicated) power supply. 
This is because in this way the level translator IC outputs on the module side (i.e. GE865 inputs) 
will work at +3.8V interface levels, damaging the module inputs.