5.2. SST-2450 Settings
When setting the SST-2450, you should first use a wire to connect the SET
and GND pins. Quickly power off and power on the SST-2450, then launch the
setting software program. There are only 3 steps required to make your settings.
setting software program. There are only 3 steps required to make your settings.
1. Open a Serial Port.
2. Setting the operating mode.
3. Exit the program.
2. Setting the operating mode.
3. Exit the program.
When setting the operating mode, please refer to the following steps:
When you set the SST-2450, you should never use the following
settings:
settings:
SST-2450 (A)
SST-2450 (B)
Half-duplex
Half-duplex
Master
Slave
These settings will cause the SST-2450 set as the Master to be
always on high power status and will cause the SST-2450 to fail. Please
note that this situation isn’t covered by our warranty.
note that this situation isn’t covered by our warranty.
The correct settings are as follows:
SST-2450 (A)
SST-2450 (B)
Full-duplex
Full-duplex
Master
Slave
or
SST-2450 (A)
SST-2450 (B)
Half-duplex
Half-duplex
Slave
Slave
If you have a SST-2450 Network (i.e. more than 2 SST-2450 devices), you
are only able to use the following specific setting for all of your SST-2450
devices:
Half-duplex