ZXG10-BTS (V2.9) Technical Manual 
84 
Confidential and Proprietary Information of ZTE CORPORATION  
F
I G U R E  
6 5
 
R
A D I O  
R
E S O U R C E  
I
N D I C A T I O N
 
 
MS 
LAPD
FURRM 
HPIMa
LAPD 
BSC 
OAMM 
DL_ DATA_REQ (RF RES IND) 
MPH_CHPIndToRR 
(CHP MEAS IND) 
 (RF RES IND) 
 Period value 
 
 
It notifies the BSC the interference level of the idle channel of one TRX. 
The interference level value of the idle channel is provided by the CHP, 
and reported in the CHP MEASUREMENT INDICATION message, just like 
the measurement report. This message is reported once every 102 frames 
(51 multiframes) or 104 frames (26 multiframes). 
Load Management 
1. Load indication 
The procedure of load indication on the common channel is shown in 
Figure 66. 
F
I G U R E  
6 6
 
P
R O C E D U R E   O F  
L
O A D  
I
N D I C A T I O N   O N  
P
U B L I C  
C
H A N N E L
 
 
MS 
PAGCHM 
FURRM 
HPIMa
LAPD 
BSC 
OAMM 
DL_ DATA_REQ (CCCH LOAD IND) 
MPH_CHPIndToRR 
(CHP RACH LOAD 
IND) 
  (CCCH LOAD IND) 
PAG_DATA_IND 
(PAG PCH LOAD 
IND) 
DL_ DATA_REQ (CCCH LOAD IND) 
 (CCCH LOAD IND) 
Period value & threshold 
 
 
The BTS gives the BSC the load information in a specific CCCH timeslot, 
mainly involving RACH and PCH loads. 
The CHP calculates the exact load on the RACH. The PAGCHM 
calculates the load on the PCH. The thresholds and sending period are 
configured in the OAMM. 
2. General overload