ZTE Corporation ZXG-BTS2 Benutzerhandbuch

Seite von 139
 
ZXG10-BTS (V2.9) Technical Manual 
12 
Confidential and Proprietary Information of ZTE CORPORATION  
It includes the system control module and implements the power-
on sequence for application processes. In addition, this layer 
includes some miscellaneous functions of the operating system 
such as redirection of the printing messages. 
iii. LNKDRV 
It is the device driver.  
Working with BSP, LNKDRV provides equipment-independent 
drivers for LNKCTR. At the same time, this part also includes a 
frame number synchronization module, implementing the frame 
number synchronization between active/standby CMMs, active 
CMMs of the master rack and the secondary rack, and master CMM 
and TRMs. 
iv. LNKCTRL 
It is the communication link control layer module.  
It consists of multiple communication link control modules, like 
LapD, HDLC, LMComm.  
 
LapD communication link control module   
LapD is the communication link control module of the Abis interface. 
 
HDLC communication link control module   
HDLC is the communication link control module inside the rack. 
They all communicate in a point-to-point way. 
There are three types of communication links: CCComm, CMComm 
and CTComm.  
CCComm: The CCComm is the auxiliary communication link 
between the master CMM of the master rack and that of the slave 
rack. Physically, it is a 2 M PCM line, which facilitates the 
centralized data collection of LMU. 
CMComm: As the communication link between the active CMM and 
the standby CMM, it implements the data synchronization between 
the active CMM and standby CMM. Physically, it uses 1 M HW. 
CTComm: As the communication link between the active CMM and 
1 ~ 12 TRMs of its racks, the CTComm implements the parameter 
configuration of TRM and alarm collection. Physically, it uses a 64 
Kbit/s timeslot in 4 M HW.  
 
LMComm 
Foreground/background link control module with RS232 as its 
physical interface. It is a self-defined point-to-point link control 
protocol and character-oriented single-bit stop and wait protocol. 
5.  APP layer:  
It is the application layer, consisting of three parts:  
i. O&M 
As the core of the application layer, it receives the O&M messages 
of the Abis interface and implements parameter configuration, 
status and alarm management, software version management, 
equipment test and external alarm collection.