Wilcoxon Research Inc. MAYMAN Benutzerhandbuch
97002 Rev.01 02/03 Page 18
Absolute Maximum Ratings (Appendix B)
C1B Class 1 Radio Module
Date: February 21, 2003
Revision 1
Revision 1
Table 1 Absolute Maximum Ratings
Parameter Ratings
Units
Notes
Supply Voltage
-.45 to + 3.6
VDC
Vcc
Logic Levels
0-Vcc-.45 V
VDC
RF at RF input
+23 dBm
1 milli-Watt ref.
From 2400-2500 MHz
RF at RF input
+30 dBm
1 milli-Watt ref.
From 200-1900 MHz
RF at RF input
+27 dBm
1 milli-Watt ref.
From 2600-4500 MHz
ESD at RF input
10
KV
Human body model (EN 61000-4-2) With gnd
connection at antenna and I/O connector
connection at antenna and I/O connector
Storage Ambient Temp.
-55 to +125
Deg Centigrade
Operating Ambient Temp.
-40 to +85
Deg Centigrade
Caution: This device is ESD sensitive until properly connected.
For further technical assistance or product information: 1-800-WILCOXON 301-330-8811 Email:
wireless@wilcoxon.com
www.wilcoxonwireless.com
© Wilcoxon Research, Inc. 2003 Rev .1