Woosim System Inc. WSP-R240X Benutzerhandbuch
WSP-R240 Rev. 6.1
18
POWER button : use for changing OPTION status. (
Error Lamp
)
FEED button : use for changing MODE status. (
Power Lamp
)
[Example] The defaults of the printer are :
RS-232C / 9600 bps / 8 data bit / No parity / 1 stop bit / Density low
/ Mark use / Sensor low / Power down 5 minute
If a user wants to modify the defaults with
Bluetooth / 57600 bps / 7 data bit / Odd parity / 2 stop bit
/ Density high / Mark no use / Sensor medium1 / Power down no use
Press FEED & POWER Button during the
Error Lamp
flickers 5 times.
You will see the
Power Lamp
and the
Error Lamp
flickers once.
Press the POWER Button twice and the
Error Lamp
flickers 3 times.
And then, interface mode has set to Bluetooth mode.
When you press FEED button once again,
Power Lamp
flickers twice and
the
Error Lamp
flickers once.
Press POWER Button 3 times,
Error Lamp
flickers 4 times.
And then, baudrate has set to 57,600 bps.
When you
press FEED button once again,
Power Lamp
flickers 3 times
and the
Error Lamp
flickers twice.
Press POWER Button once,
Error Lamp
flickers once.
And then Data Bit has set to 7 data bit.
When you press FEED Button once again,
Power Lamp
flickers 4 times
and the
Error Lamp
flickers once.
Press POWER Button once,
Error Lamp
flickers twice.
And then the Parity bit has set to Odd parity bit.