 POWER button : use for changing OPTION status. (
Error Lamp
 FEED button      : use for changing MODE status.    (
Power Lamp
 
[Example] The defaults of the printer are : 
RS-232C / 9600 bps / 8 data bit / No parity / 1 stop bit / Density low     
/ Mark use / Sensor low / Power down 5 minute 
 
If a user wants to modify the defaults with 
Bluetooth / 57600 bps / 7 data bit / Odd parity / 2 stop bit   
/ Density high / Mark no use / Sensor medium1 / Power down no use 
 
 
 
Press FEED & POWER Button during the 
Error Lamp
 flickers 5 times. 
 You will see the 
Power Lamp
 and the 
Error Lamp 
flickers once. 
 Press the POWER Button twice and the 
Error Lamp
 flickers 3 times. 
      And then, interface mode has set to Bluetooth mode. 
 
When you press FEED button once again, 
Power Lamp
 flickers twice and 
    the 
Error Lamp
 flickers once. 
   Press POWER Button 3 times, 
Error Lamp
 flickers 4 times. 
And then, baudrate has set to 57,600 bps
 
When you
 
press FEED button once again, 
Power Lamp
 flickers 3 times   
and the 
Error Lamp 
flickers twice. 
     Press POWER Button once, 
Error Lamp
 flickers once. 
  And then Data Bit has set to 7 data bit
 
When you press FEED Button once again, 
Power Lamp
 flickers 4 times 
    and the 
Error Lamp
 flickers once. 
     Press POWER Button once, 
Error Lamp
 flickers twice. 
        And then the Parity bit has set to Odd parity bit