Airaya Corp AI108 Benutzerhandbuch

Seite von 28
 
- 11 - 
Hardware Installation 
 
Connecting the Indoor Unit 
 
 
Front Panel View 
 
 
 
 
 
 
 
 
 
 
The indoor unit connects your company network to the AI108 and delivers both data 
and power to the outdoor unit. The indoor unit features the following LED status 
indicators: 
 
LED 
Indication 
Detect (green) 
Compatible load detected and Ethernet link established between 
indoor and outdoor units. 
Fuse blown (yellow) 
The unit includes a fuse to help protect the attached equipment 
from power surges and lightning damage. A lit LED indicates 
that the fuse needs to be replaced. 
Power (green) 
External power applied 
48V out (green) 
Power over Ethernet is active 
 
Before you mount the indoor unit to a fixed location, consider the following 
requirements to determine the optimal placement:   
 
• 
The cable length from the Ethernet network to the indoor unit must not exceed 
320 ft (100 meters). 
• 
The distance from the indoor unit to the outdoor unit must not exceed the 
length of the Category 5E cable included with the AI108 wireless bridge 
(between 50 and 300 ft, specified by part number
1
). 
• 
Placement must allow for easy access to disconnect the indoor unit from the AC 
outlet if necessary. 
 
                                                 
1
 Refer to section Models and Ordering Information for details