Appendix C: Weatherproofing RF Cable Connections 
 
Step 1. Connecting Cable Assembly to Antenna or Enclosure 
 
Attach RF cable assembly to antenna/enclosure by fastening the N-type male 
connector to the N-type female connector. Notes: Ensure both connectors are 
clean and dry. Hand-tighten firmly. 
 
 
 
Step 2. Sealing the Connector Assembly 
 
Tightly wrap the connectors with 2 layers of rubber tape (butyl). Notes: Rubber 
tape should seal entire connection and extend 1 inch beyond antenna 
connector/cable assembly. 3M 3339 tape works very well in this application. 
 
 
 
Step 3. Covering Rubber Tape with Electrical Tape 
 
Tightly wrap the rubber tape with 2 layers of electrical tape. Note: Electrical 
tape should extend 1 inch beyond rubber tape to ensure full coverage. 
 
- 60 -