•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult a qualified electrician.
•  Vizia™ RF electronic switches are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ RF controllers.
•  Recommended minimum wall box depth is 2-1/2".
WARNINGS AND CAUTIONS
:
•    Use only one (1) Vizia
TM 
 RF electronic switch in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs.
•  Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).
•  Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•  Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Single Pole (One location) or 3-Way (Multi-location)
Scene Capable Electronic Switch
Cat. No. RZS15-1L, (Lighted)
Incandescent-1800W – Magnetic Low-Voltage-1800VA (1440W)
Electronic Low-Voltage-1880W – Fluorescent-1800VA – Supplemental-1/2 HP
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
DI-000-RZS15-00A-X0
 Tools needed to install your Switch:
Slotted/Phillips Screwdriver 
Electrical Tape 
Pliers 
 
Pencil 
 
 
Cutters 
 
Ruler
Changing the color of your Switch:
Your switch includes three color options. The switch ships with the White 
frame attached. To change color of frame, proceed as follows:
Line up tabs 
and press in 
side to attach
Push in 
side at tab 
to release
INSTALLING YOUR SWITCH
NOTE: Use check boxes           when Steps are completed.
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
WARNING: 
TO AVOID FIRE SHOCK OR DEATH; TURN 
OFF POWER at circuit breaker or fuse and test that power is 
off before wiring!
 
Step 1
2
4
3
1
2
4
1
5
3
Single Pole
1.
  Line (Hot)
2.  Neutral
3.  Ground
4.  Load 
3-Way
1.
  Line or Load (see important instruction below)
2.  Neutral
3.  Ground
4.  First Traveler – note color
5.  Second Traveler – note color. NOTE: For 
matching remote w/LEDs installation, the 
First Traveler becomes Line Hot.
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble any of 
these configurations, consult a qualified electrician.
 
Step 2
 
Step 3
Compatible with
enabled products!
TM
IMPORTANT : For 3-Way applications, note that one of the screw terminals 
from the old switch being removed will usually be a different color (Black) 
or labeled Common. Tag that wire with electrical tape and identify as the 
common (Line or Load) in both the switch wall box and remote wall box.
BK
WH
YL/RD RD
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal Label:
Use Terminal for 3-Way or More Applications Only.
For Single-Pole Applications, Do Not Remove This
Label.
4
3
2
Terminal
Screw marked
White (WH)
1
Single Pole Wiring Application:
 
Step 4a
Preparing and connecting wires:
This switch can be wired using side wire terminal screws or 
through backwire openings. Choose appropriate wire stripping 
specifications accordingly.
•  Make sure that the ends of the wires from the wall box are 
straight (cut if necessary).
•  Remove insulation from each wire in the wall box as shown.
•  For Single-Pole Application, go to Step 4a.
•  For 3-Way Coordinating Remote (no LEDs) Application, go to Step 4b.
•  For 3-Way Matching Remote (with LEDs) Application, go to Step 4c.
5/8" 
(1.6 cm)
Strip Gage 
(measure bare 
wire here)
Cut 
(if necessary)
Side Wire Connection 
Side wire terminals accept #14 
AWG solid wire copper only.
Back Wire (either hole may be used) 
Back wire openings use #14-12 AWG 
solid wire copper only
Hot (Black)
Neutral (White)
Load
Switch
BK
WH
Black
White
RD
Green
Ground
YL/RD
Line 
120VAC, 60Hz
Use Terminal for 3-Way or
More Applications Only.
For Single-Pole Applications,
Do Not Remove This Label.
WIRING SWITCH:
Connect wires per WIRING DIAGRAM as follows:
•  Green or bare copper wire in wall box to Green terminal screw.
•  Line Hot wall box wire to terminal screw marked "BK".
•  Load wall box wire to terminal screw marked "RD".
•  Line Neutral wall box wire to terminal screw marked "WH".
•  Switch terminal screw marked "YL/RD" should have Red insulation 
label affixed. 
 
NOTE: If insulating label is not affixed to terminal screw marked "YL/RD", 
use electrical tape to cover.
• 
Proceed to Step 5.
 
Step 4a cont'd
BK
WH
YL/RD RD
Coordinating Remote
Switch
5
2
1
4
3
BK
WH
YL/RD RD
4
3
1
5
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
White (WH)
2
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Yellow/Red
(YL/RD)
3-Way Wiring with Coordinating Remote 
(no LED) Application:
 
Step 4b
Hot (Black)
Neutral (White)
Coordinating Remote (no LED)
YL/RD
YL/RD
RD
WH
RD
BK
Black
BK
WH
White
Line 
120VAC, 60Hz
Green
Ground
Green
Ground
(unused)
(unused)
Load
Switch
WIRING SWITCH:
Connect wires per WIRING DIAGRAM as follows:
NOTE: The switch must be installed in a wall box that has a Line Hot 
connection.
NOTE: Maximum wire length from switch to all installed remotes 
cannot exceed 300 ft (90 m).
•  Green or bare copper wire in wall box to Green terminal screw.
•  Line Hot (common) wall box wire identified (tagged) when 
removing old switch
  to terminal screw marked "BK".
•  First Traveler wall box wire to terminal screw marked "RD" 
(note wire color).
•  Remove Red insulating label from terminal screw marked "YL/RD".
•  Second Traveler wall box wire to terminal screw marked "YL/RD"  
(note wire color). This traveler from the switch must go to the 
terminal screw on the remote marked "YL/RD".
•  Line Neutral wall box wire to terminal screw marked "WH".
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: "BK" and "RD" terminals on coordinating remote are unused.
Tighten both screws.
NOTE: Maximum wire length from switch to last remote is 
300 ft (90 m).
•  Green or bare copper wire in wall box to Green terminal screw.
•  Load wall box wire identified (tagged) when removing old switch to 
First Traveler 
(note color as above).
•  Second Traveler wall box wire 
(note color as above) to terminal 
screw marked  "YL/RD". This traveler from the remote must go to 
the terminal screw on the switch marked "YL/RD".
•  Remove White insulating label from terminal screw marked "WH". 
•  Line Neutral wall box wire to terminal screw marked "WH". 
•  Proceed to Step 5.
 