Leviton Manufacturing Co. Inc. VRP15 Benutzerhandbuch

Seite von 3
Scene Capable Plug-In Appliance Module
Cat. No. VRP15-1LW
Incandescent: 1800W      Fluorescent: 1800VA 
Resistive: 15A     Motor: 1/2HP
Rated: 120VAC, 60Hz
INSTALLATION INSTRUCTIONS
DI-030-VRP15-02A
 INTRODUCTION
Leviton’s ViziaRF +
TM
 components are 
designed to communicate with each other 
via Radio Frequency (RF) to provide remote 
control of your lighting. Using RF technology 
allows Leviton to provide the greatest signal 
integrity possible. Each module in Leviton’s 
Vizia RF +
TM
 component line is a Z-Wave
®
 
enabled device. In a Z-Wave
®
 network, each 
device is designed to act as a router. These 
routers will re-transmit the RF signal from one 
device to another until the intended device 
is reached. This ensures that the signal is 
received by its intended device by routing the 
signal around obstacles and radio dead spots.
CAUTION:
Remember to exercise good common sense 
when using the Timer features of your remote, 
especially when scheduling unattended 
devices. There can be some unexpected 
consequences if not used with care. For 
example, an empty coffee pot can be remotely 
turned on. If that should happen, your coffee 
pot could be damaged from overheating. If an 
electric heater is turned on by remote control 
while clothing is draped over it, a fire could 
result. 
DO NOT USE the remote for the control 
of high power heating appliances such as 
portable heaters. 
DO NOT change location 
after unit is enrolled in Z-wave
®
 network.
NOTES:
•  If using a non-Leviton Programmer/Remote,
refer to the Programmer/Remote instruction 
sheet for including a device.
•  If using VRCPG install checklist go directly to
step B.
A) If using a Leviton Z-Wave
®
 Programmer/
Remote, Cat. No. VRCPG, press the Menu
button and scroll down to System. Press the 
center button to select System Menu. Choose 
Advanced. Press the center button to select 
Advanced Install.
Including Scene Capable 
Plug-In Appliance Module 
into Z-Wave
®
 Network:
 
Step 3
Attaching Scene Capable 
Plug-In Appliance Module to 
Wall Receptacle:
 
Step 2
•  Plug the Scene Capable Plug-in Appliance
Module into wall receptacle. Verify that 
receptacle is live. If controlled by a wall switch, 
the switch 
must be kept ON at all times.
Attaching Load to Scene 
Capable Plug-In Appliance 
Module:
 
Step 1
NOTE: In order to use your Vizia RF +
TM
 Scene 
Capable Plug-In Appliance Module in a Z-Wave
®
 
network, it must be included in the network using 
a Primary Programmer/Remote, such as Leviton’s 
Cat. No. VRCPG. Before including your module,
please refer to the Primary Programmer/Remote 
instruction sheet for complete information. 
Refer 
to Step 3 for further details.
•  Locate load to be controlled by Scene Capable
Plug-In Appliance Module and ensure it is 
fully operational. Attach load plug into module 
receptacle noting proper polarity of blades.
NOTE: Use check boxes           when Steps are 
completed.
INSTALLING YOUR APPLIANCE MODULE
B) While standing close to the module 
(approximately 1 foot), press the center 
button to <Include> device in the network.
 
NOTE: Only one device may be included 
at a time. 
DO NOT put multiple devices into 
the Inclusion mode at any time.
C) While the Programmer/Remote is in the 
Inclusion mode and the LED is ON on 
the Scene Capable Plug-In Appliance 
Module, press the ON/OFF button on the 
module. The Programmer/Remote will verify 
inclusion and the LED will turn OFF on the 
Scene Capable Plug-In Appliance Module.
 
NOTE: If the LED on the Scene Capable 
Plug-In Appliance Module turns solid 
Red while including, there has been 
a communication error. 
Refer to 
Troubleshooting section.
D) The Primary Programmer/Remote will 
assign a node ID number (Name) for this 
module.
 
NOTE: This ID number (Name) will be 
stored in the controller to be used for future 
reference.
 
NOTE: You may name or edit this device at 
this time.
E) The module is now installed in the 
network.
NOTE: If the module has been successfully 
included in the network and the user tries to 
include it again without first excluding it from 
the network, the module will retain the first 
node ID it had received and ignore the second.
•  Switch ON/OFF
•  Scene capable
•  ON/OFF LED
•  Two way communication
•  RF reliability
•  Ease of installation – No new wiring
•  Compatible with other Z-Wave
®
 enabled 
devices
 FEATURES
 
Step 2 cont’d
 
Step 3 cont’d
Programming and 
ON/OFF Button
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Programmer/Remote
Cat. No. VRCPG
Center Button
Menu Button
WARNINGS AND CAUTIONS:
•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult an electrician.
WARNINGS AND CAUTIONS:
•  Unplug unit when servicing fixture or changing bulbs.
•  Save this instruction sheet. It contains important technical data along with testing and
troubleshooting information which will be useful after installation is complete.