CommScope Technologies LLC RP-A2014 Benutzerhandbuch

Seite von 70
Appendix C Installation troubleshooting 
C-2
913020 10.05 April 2015
D
R
A
F
T
Controller LED patterns
The Controller has four LEDs on the front panel. The following table shows
Display pattern for each LED
What the pattern indicates
Action to take, if any, to resolve the issue
LED
Display Pattern
Indicates
Action to Take
STATUS
Green, solid
Power On
Sectors up
None
Amber, solid
Self-test failure
Green, blinking
Firmware upgrade
None
Amber, blinking
Configuring from DMS
Red, solid
Error in system - software or 
hardware issues detected
RU ERROR
Green, solid
Power On 
None
Amber, solid
Self-test failure
Amber, blinking
No Radio Points connected
Off
Radio Points connected, 
firmware upgrade
None
Red, blinking
Radio Point alarm - PLL state 
unlock; service impacting alarm 
from Radio Point
TIMING LED
Green, solid
Power On, timing
None
Amber, solid
Self-test failure
Amber, blinking
No timing
Off
Firmware upgrade
None
Red, solid
Error