Figure 10: Power off timing sequence
Table 10: Power off timing
Symbol
Parameter
Time value
Min.
Typ.
Max. Unit
Toff
The time pulling PWRKEY down to power off
0.5
-
5
s
TpD-
The time to indicate disconnecting from the network
-
-
2
s
Tpw-
The time to indicate the module power off completely
-
-
2
s
Tuart
The time to disable UART
-
-
3
s
Tusb
The time to disable USB
-
-
2
s
Trestart
The time to power on again after Tpw-
0
-
-
s
User can also use the AT command
AT+CPOF
to power down the module. After that, the AT
commands cannot be executed any longer. The module enters the POWER DOWN mode.
VDD_EXT pin can be used to detect whether module is powered on or not. When module is powered
on and firmware goes ready, VDD_EXT will be high level.
Note: For details about “AT+CPOF”, please refer to Document [1].
3.2.3
Reset Function
SIM7100C also have a RESET pin (PIN4) to reset the module. This function is used as an emergency reset
only when AT command “AT+CPOF” and the PWRKEY pin has no effect. User can pull the RESET pin