Advanced Control Technologies Inc. 0763-03 Benutzerhandbuch

Seite von 5
LSM-20 Instructions 
P/D 112609
LSM-20
by EVOLVE GUEST CONTROLS
1
Evolve Radio Frequency (RF) Controlled, 120 VAC, 
Wall Mounted Switch, 3-Way, Release 3.1
LSM-20
LSM-20 WaLL Mounted SWitch
The LSM-20 Wall Mounted 3-Way Switch is a component of the Evolve lighting control system.  Wire the Wall Mounted Switch in place of the 
standard wall switch according to the diagram above and program from the Wireless Controller to operate loads.  Inclusion of this Switch on the 
IR-100 Wireless Controller menu allows remote ON/OFF control of lamps connected. 
This Wall Mounted Switch is designed to work with other Evolve enabled devices. Evolve nodes of other types can be added to the system and 
will also act as repeaters if they support this function of repeating the signal received to other modules in the system. 
As part of a Evolve network, the LSM-20 will also act as a wireless repeater to insure that commands intended for another device in the network 
are received. This is useful when the device would otherwise be out of the radio range of the wireless controller. 
There are no field repairable assemblies on this unit.. If service is needed, the unit must be returned where purchased.
danGeR! Shock hazaRd. Read and understand these instructions before installing. This device is intended for installation in accor-
dance with the National Electric code and local regulations in the United States, or the Canadian Electrical Code and local regulations in Canada. 
It is recommended that a qualified electrician perform this installation.
Make sure the load controlled by the switch does not exceed 2400 watts. For indoor use only. Retain instructions for future use. 
inStaLLation 
Wire this Switch in place of a current wall switch according to the diagram above. 
When used, AS101’s are required to be wired to the same line (or neutral) which is also wired to the master unit as well as the load 
being controlled, and not wired to any other neutral. If multiple neutrals are tied together in one box, separate the neutrals to preserve the integrity 
of the LSM-20 circuit. caution! Do not wire unit “live” (with power on the circuit) and do not allow the yellow wire to contact line voltage, 
neutral or ground or you will damage the device. Refer to your Controller operating instructions to add this module under the command of the 
Wireless Controller.
incLudinG LSM-20 to the netWoRk
SteP 1.  Prepare the Controller to include a unit to the network by adding it to a group (method of adding a node to the network). Refer to 
controller instructions. 
Shown with supplied 
Decora
TM
 trim plate
note:  This  module  must  be  “Included  in  the  Network” 
only where it will be permanently installed. The proper 
operation of this node in the mesh network is dependent 
on it knowing its location with respect to other nodes. You 
cannot “test bench” configure this module, then install.