Gemalto M2M GmbH ELS61-USA Benutzerhandbuch

Seite von 113
Cinterion
®
 ELS61-USA Hardware Interface Description
3.7 Blocking against RF on Interface Lines
83
els61-usa_hid_v01.040a
2017-08-31
Confidential / Preliminary
Page 82 of 113
The following table lists for each signal line at the module‘s SMT application interface the EMI
measures that may be implemented.
Table 19:  
EMI measures on the application interface
Signal name
EMI measures
Remark
A
B
C
D
E
CCIN
x
x
CCRST
x
The external capacitor should be not higher 
than 30pF. The value of the capacitor 
depends on the external application.
CCIO
x
CCCLK
x
RXD0
x
x
x
x
x
TXD0
x
x
x
x
x
CTS0
x
x
x
x
x
RTS0
x
x
x
x
x
GPIO1/DTR0
x
x
x
x
x
GPIO2/DCD0
x
x
x
x
x
GPIO3/DSR0/SPI_CLK
x
x
x
x
x
GPIO4/FST_SHDN
x
x
x
x
x
GPIO5/LED
x
x
x
x
x
GPIO6/PWM2
x
x
x
x
x
GPIO7/PWM1
x
x
x
x
x
GPIO8/COUNTER
x
x
x
x
x
GPIO11-GPIO15
x
x
x
x
x
GPIO16/RXD1/MOSI
x
x
x
x
x
GPIO17/TXD1/MISO
x
x
x
x
x
GPIO18/RTS1
x
x
x
x
x
GPIO19/CTS1/SPI_CS
x
x
x
x
x
GPIO20/DOUT
x
x
x
x
x
GPIO21/DIN
x
x
x
x
x
GPIO22/FSC
x
x
x
x
x
GPIO23/BCLK
x
x
x
x
x
GPIO24/RING0
x
x
x
x
x
I2CDAT 
x
x
The rising signal edge is reduced with an 
additional capacitor.
I2CCLK x
x
V180
x
x
x
VCORE
x
x
x
BATT+
RF
 (pad 53)
x
x
Measures required if BATT+
RF
 is close to 
internal RF antenna -
e.g., 39pF blocking capacitor to ground
BATT+
BB
 (pad 204)
x
x
VUSB
x
x
x
USB_DP
It is not allowed to use any external ESD or 
EMI components at this interface signal 
lines.
USB_DN