7 APPENDIX 
7.1  Recommendations for power supply 
It is recommended to use the PS002 power supply. Also any other power supply in 
the range of 10.8 ... 31,2 V DC can be used. It should be able to deliver 2A peak 
current (for 577µs, rise time 10µs, period 4.615ms, caused by GSM-typical radio 
transmission), where the ripple voltage of the power supply is recommended to be 
lower than 300mV. 
If the power supply is using input-voltages of more than 50 Vrms 
 
or 75 V DC it is the response of the applicant to conform with the safety requirements 
of Telecommunication Terminal Equipment (such as 73/23/EEC). 
7.1.1  External cable for power supply 
Power cable, included in the package, shall be used for power supply connection. 
The external power cable is a four-conductor cable with stripped and tinned ends. 
Connect the white and yellow leads of the external power cable to the positive side 
of the DC power source. Connect the brown lead of the external power cable to 
the negative side of the DC power source. The green lead of the external power 
cable should be left open (not connected). 
COUTION:  
Observe polarity when connecting the external power cable. 
Incorrect input polarity can damage the power adapter. 
The connector of power cable is a Micro-Fit 3.0 one. 
Part number: 43025-0400 (male) 
 
 
Figure 43: View of external cable for power supply 
 
This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission. 
Page 40