AP 7161 Access Point Installation Guide  
17 
 
 
The GE2 port  on the  unit  can  be used  if a second data connection for an external  device (e.g. surveillance  camera) 
is required.  Ensure  the  GE2 WAN port has been configured to permit an attached external device during the 
configuration  process. 
 
When  making connections  using these  ports,  a properly  rated  RJ45 connector  is required.  One weatherproof  RJ45 
plug  kit  is provided  with  each access point.  When  connecting  cables to the AP 7161 Ethernet  ports,  follow the 
instructions  in the connector packaging and tighten  the connectors to create a weatherproof  seal. Shielded cables 
are required. 
 
AP 7161 Grounding Screw 
 
The grounding   screw  is located  to  the  right  of  the  GE1/POE port  and  above  the  GND symbol. 
 
 
 
 
 
WARNING!   
The grounding  cable for  an AP 7161 must be at a minimum  a #10 gauge wire  cross 
section. 
 
 
The grounding cable can be attached  to the unit  using one of three recommended methods. Using an 8mm socket 
and driver: 
 
• Loosen the grounding  screw and insert  the grounding  cable into  the hole below  it. Tighten the grounding  screw 
to 30 inch pounds (lbf-in). 
 
• Loosen the grounding  screw and wind  the grounding  cable around the screw.  Tighten the grounding  screw to 30 
inch pounds (lbf-in). 
 
• Attach a ring lug to the grounding cable and remove the grounding screw to attach the ring lug to the access 
point.  Secure it to the unit by reinserting the grounding screw. Tighten the grounding screw to 30 inch pounds 
(lbf-in).