AP 7161 Access Point Installation Guide 
 
 
Environmental Specifications 
 
Operating Temperature             -40 to +70 degrees celsius 
Storage Temperature                -40 to +85 degrees celsius 
Operating Humidity                   5-95 percent 
Operating Altitude                     8,000 feet 
 
Storage Altitude                        30,000 feet 
Electrostatic  Discharge  
EN61000-4-2. Air +/-15kV, Contact +/-8kV 
Enclosure  
Outdoor IP67 rated, corrosion resistant enclosure 
ASTM B117 salt, fog, and rust resistance 
Wind  Ratings 
150 mph * (unit bracket measurement) 
Operational  Shock  
IEC60721-3-4, Class 4M3,  MIL  STD 810F 
Operational  Vibration                 IEC60721-3-4, Class 4M3 
 
Radio Specifications 
 
Network  Standards 
IEEE 802.11 a/b/g/n,   802.11e, 802.11i, WPA2, WMM,  and WMM-UAPSD 
 
Supported Data Rates 
802.11b/g:1,  2, 5.5, 11, 6, 9, 12, 18, 24, 36, 48 and 54 Mbps 
802.11a: 6, 9, 12, 18, 24, 36, 48 and 54 Mbps 
802.11n: MCS 0-15 up to 300 Mbps 
 
802.11n Support 
3x3 MIMO  with  2 spatial streams 
20MHz and 40MHz channels supported 
300Mbps data rates per radio 
Packet aggregation (AMSDU,AMPDU) 
Reduced interframe spacing 
 
802.11 b/g/n 
Operating  frequency  2.4 - 2.483 GHz 
Maximum EIRP 32  dBm* 
 
802.11 a/n 
Operating  frequency  4.940  GHz - 4.990  GHz and  5.25  GHz - 5.35  GHz and  5.470  GHz - 5.825  GHz 
Maximum EIRP 34  dBm* 
 
*Maximum EIRP may vary based on local  standards for the area  of deployment.