Setup and Deployment  
Assemble the IAP using the following procedure: 
1.  If desired, mount the IAP6300 box using the enclosed bracket.  Refer to Figure 8. 
2.  Place the bracket at the desired position on the pole   The bracket can accommodate 
pole diameters between 1-3.5 inches.  The bolts supplied with the bracket will 
accommodate pole diameters of  2.75 – 3.5 inches.  If needed, obtain a ¼-20 hex bolt of 
an appropriate length for pole diameters between 1-2.75 inches (stainless steel bolts are 
recommended). 
3.  Adjust the position of the box so that the antenna will be in a vertical position. Tighten 
the pivot and angle locking bolts on the shaft of the bracket as shown in Figure 9 
4.  Insert the antenna into the N-type Connector on the top of the box, and rotate to close. 
5.  Insert the IAP Power Plug into the 4-pin connector. 
6.  Install the weatherproof connector on the Ethernet cable as described at: 
http://www.siemon.com/installation_instructions/pdf/IMAXIndustrialUTPPlug.pdf
 
7.  Insert the Ethernet Cable into the RJ-45 port and tighten the connector to ensure a 
weatherproof seal. 
8.  If used, insert the Media Converter Power Cable into the 3-pin connector. 
9.  The Test Port is unused during deployment  
 
6 x 32 x 3/4
Angle Locking Bolt
1/4 x 1 inch Pivot Bolt
(Requres 7/16 Wrench)
 
Figure 9. 
Bracket Adjustment Bolts 
 
Deployment 
The IAP may be mounted on a pole having a diameter of 1-3.5 inches, utilizing the provided 
bracket.  The antenna must have a separation distance of at least 2 meters from the body of all 
persons and must not be co-located or operating in conjunction with any other antenna or 
transmitter.  Users and installers must be provided with antenna installation and transmitter 
operating conditions to satisfy RF exposure compliance.