Cisco 15454-MRP-L1-54.1= Datenbogen

Seite von 14
 
Cisco Systems, Inc.  
All contents are Copyright © 1992–2004 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement. 
Page 12 of 14 
 
 
Specification 
  
Optical Receiver 
Type 
APD 
Sensitivity, 3R mode (P
Rmin
 to P
Rmax
FEC off; BER = 10E-12; OSNR >14 dB 
FEC on; BER = 10E-15; OSNR >14 dB 
FEC off; BER = 10E-12; OSNR >11 dB 
FEC on; BER = 10E-15; OSNR >7 dB 
Sensitivity, 2R mode (P
Rmin
 to P
Rmax
BER = 10E-12; OSNR >15 dB 
Note: Optical signal to noise ration (OSNR) defined at 0.5-nm bandwidth 
  
–28 to –9 dBm 
–31 to –9 dBm 
–23 to –9 dBm 
–23 to –9 dBm 
  
–24 to –9 dBm 
 
 
Transmission penalties 
3R mode—Dispersion power penalty (FEC on or off) 
3R mode—Dispersion OSNR penalty (FEC on or off) 
2R mode—Dispersion power penalty
3
 
  
2 dB @ +/–5400 ps 
2 dB @ +/–5400 ps 
3 dB @ +/–3300 ps 
Chromatic dispersion tolerance (D
LRmax
Up to +/–5400 ps/nm (360 km in 3R mode)  
Receiver reflectance (maximum) 
–27 dB 
Input wavelength bandwidth (
λ
c_rx
Third window, ITU G.692,  
1530–1565 nm 
Management 
Card LEDs 
Failure (FAIL) 
Active/standby (ACT/STBY) 
Signal fail (SF) 
Client port LEDS (bicolor) 
Active-no alarms/alarm 
DWDM port LEDs (tricolor) 
Active/standby (protection card only)/alarm 
  
Red 
Green/yellow (Y-protection) 
Yellow 
  
Green/red 
  
Green/yellow/red 
Power 
Typical 
Maximum 
25 watts 
35 watts 
Operating environment  
Temperature 
–5 to 55°C 
23 to 131°F 
Humidity 
5 to 95% noncondensing 
Storage environment  
Temperature 
–40 to 185°F 
40 to 85°C 
Humidity 
5 to 95% noncondensing 
3. Reach in 2R mode is OSRN limited as compared with dispersion limited.