Orolia Ltd NAV-7 Benutzerhandbuch

Seite von 26
 
24 
DISPLAY ELECTRICAL INSTALLATION 
This manual is concerned only with the installation of the NAV-7 and does not cover 
the installation of any peripheral equipment connected to the NAV-7 such as 
printers, navigational systems or source of NMEA data. For proper installation and 
connection of peripheral equipment to the NAV-7 refer to the installation manuals 
for these products. 
The table below shows the connections that must be made to the NAV-7 for it to 
function correctly. 
 
Connection 
Must connect 
Optional 
Ship’s earth connection 
ü
 
 
12V or 24 V DC power supply 
ü
 
 
NAVTEX antenna 
ü
 
 
Alarm Relay 
ü
 
 
NMEA or IBS time reference 
See Note 1 
See Note 1 
Integrated Bridge/Navigation System 
 
ü
 
External printer 
 
ü
 
Note 1: Connecting a time reference (eg a GPS receiver) is highly recommended. 
 
Ship’s earth connection 
The earth terminal on the rear of the NAV-7 display must be connected to ship’s 
ground by the earth cable supplied. The earth connection should be kept as short 
as possible. 
 
Safety Warning 
To ensure the best possible protection of the NAV-7 from static electricity 
or nearby lighting strikes, the pre-fitted green grounding wire (connected 
to the safety earth spade) must be connected to a nearby (hull) electrical 
grounding point.