Raven Industries E1005300 Benutzerhandbuch
2-28-08
REV C
ELECTRONIC SYSTEMS DIVISION – ST. LOUIS
••••
4372 GREEN ASH DRIVE
••••
EARTH CITY
••••
MO 63045-1231
TELEPHONE (314) 291-2712 FAX (314) 291-0773
R A V E N
I N D U S T R I E S
2.4GHz System Manual
Configuration:
Head is Motor 1
Foot is Motor 2
Control Board Status Light:
1. Light ON Solid – Learn button pressed, learning coordinators or after power up the power
supplies fails to stabilize.
2. Light OFF – No Power.
3. Flash Pause – The light is on for .1 seconds off for 1.5 seconds. The unit is a slave node
control box in a multi node system.
4. Flash Fast – The light is on for .1 seconds off for .1 seconds. The unit is in learning mode.
5. Flash Slow – The light is on for .5 seconds off for .5 seconds. The unit is a coordinator.
6. Flash Code - The light will flash 1 to 5 times on a .1 second interval pause for .6 seconds
flash 1 to 5 times and pause for 2 seconds. It will then repeat this. The flashes can be
interpreted as a code by counting them. The first set of flashes are in the tens column and the
second set is the ones column. Example if it flashes 3 time pauses then 4 flashes the codes
is 34. If 2 or more error code are present at the same time the code with the higher number
will be displayed. Codes will display for 20 seconds after error has been cleared.
Codes:
11 Reset Control Box
12 Vibe 1Circuit Open Fail
13 Vibe 2 Circuit Open Fail
14 Motor 1 Circuit Open Fail
15 Motor 2 Circuit Open Fail
21 Motor 1 H-Bridge Fail (H-Bridge Version Only)
22 Motor 1 On Fail
23 Motor 1 Off Fail
24 Motor 2 H-Bridge Fail (H-Bridge Version Only)
25 Motor 2 On Fail
31 Motor 2 Off Fail
32 Vibe 1 Drive Fail FET
33 Vibe 1 Switching Fail
34 Vibe 2 Drive Fail FET
35 Vibe 2 Switching Fail
41
42
43
44
45
51 5V Fail (H-Bridge Version Only)
52 12V Fail
53
54 Find Hand Control
55 Power Fail the 24V power supply has dropped below 18V