Raven Industries E1005300 Benutzerhandbuch

Seite von 9
2-28-08 
REV C 
 
ELECTRONIC SYSTEMS DIVISION – ST. LOUIS 
••••
 4372 GREEN ASH DRIVE 
••••
 EARTH CITY
••••
  MO  63045-1231 
TELEPHONE (314) 291-2712   FAX (314) 291-0773 
 
 
R A V E N  
I N D U S T R I E S 
 
 
2.4GHz System Manual 
Configuration: 
 
Head is Motor 1 
  
Foot is Motor 2 
 
Control Board Status Light: 
1.  Light ON Solid – Learn button pressed, learning coordinators or after power up the power 
supplies fails to stabilize. 
2.  Light OFF – No Power. 
3.  Flash Pause – The light is on for .1 seconds off for 1.5 seconds. The unit is a slave node 
control box in a multi node system. 
4.  Flash Fast – The light is on for .1 seconds off for .1 seconds. The unit is in learning mode. 
5.  Flash Slow – The light is on for .5 seconds off for .5 seconds. The unit is a coordinator. 
6.  Flash Code -    The light will flash 1 to 5 times on a .1 second interval pause for .6 seconds 
flash 1 to 5 times and pause for 2 seconds. It will then repeat this. The flashes can be 
interpreted as a code by counting them. The first set of flashes are in the tens column and the 
second set is the ones column. Example if it flashes 3 time pauses then 4 flashes the codes 
is 34. If 2 or more error code are present at the same time the code with the higher number 
will be displayed. Codes will display for 20 seconds after error has been cleared. 
 
Codes: 
11 Reset Control Box 
12 Vibe 1Circuit Open Fail  
13 Vibe 2 Circuit Open Fail  
14 Motor 1 Circuit Open Fail 
15 Motor 2 Circuit Open Fail 
 
21 Motor 1 H-Bridge Fail (H-Bridge Version Only) 
22 Motor 1 On Fail 
23 Motor 1 Off Fail 
24 Motor 2  H-Bridge Fail (H-Bridge Version Only) 
25 Motor 2 On Fail 
 
31 Motor 2 Off Fail 
32 Vibe 1 Drive Fail FET 
33 Vibe 1 Switching Fail  
34 Vibe 2 Drive Fail FET  
35 Vibe 2 Switching Fail  
 
41 
42 
43 
44 
45 
 
51 5V Fail (H-Bridge Version Only) 
52 12V Fail 
53  
54 Find Hand Control 
55 Power Fail the 24V power supply has dropped below 18V