PROTOCOL SPECIFICATION 
F005VP0801 
ROBERT BOSCH 
(AUSTRALIA) PTY. LTD. 
A.B.N. 48 004 315 628
 
SMARTRA III IMMOBILISER 
Page 24 of 49 
 
 
Issue Number: 
1.0 
Dev No.
 3881 
Valid from: 
14/2/06 
Print Date: 
28 March, 2007 
© THIS DRAWING IS THE EXCLUSIVE PROPERTY OF ROBERT  BOSCH (AUSTRALIA)  PTY. LTD.  WITHOUT THEIR CONSENT IT MAY NOT BE REPRODUCED OR GIVEN TO THIRD PARTIES. 
DEV04205.9/I-1 
 
5.6  Message Flow 5 - Twice IG ON or Authentication mode 
Transponder is in [learnt] state Read EEPROM is not allowed. 
5.6.1.1  Message Sequence 
Command  
06h 
53h  
4Bh  
41h  
52h  
57h 
4Eh  
54h  
15h 
Sequence 
1 - 
 2 
- 3 -
  - 
 -  3.5 
5.6.1.2  Message Flow Detail 
 
Msg 
Flow 
no. 
T
S
EMS Mode 
description 
Description 
EMS message 
Data EMS message 
Description 
Smartra Response 
Data Smartra Message 
L L V/N 
 
Twice IG ON 
or 
Authentication 
ACK request 
IDE request 
Read EEPROM 
0x49 0x02 0x06 0x08 
0x49 S 0x4B DATA  
0x49 S 0x52 PAGE 
ACK response 
IDE response 
Negative response 
0x49 0x02 0x06 0x08 
0x69 S R IDE1..4 + ERN1..6 + State byte 
00x69 S 0x15 0xXX 
 
5.6.2  Message Flow Diagram: 
 
 
ACK request
IDE request
Read EEPROM Page
T r ansp o nd er [ l ear nt ]
Smar t r a[ lear nt ]
EM S[ vir g i n,  neut r al]
Smart ra knows the EM S sw 
is new version due t o ext ra 
byt es - encrypt s RN1..4 and 
passes t o EM S
Read EEPROM  error 
message received.
0x69 S Ret   IDE1..4 + 
ERN1..6 + St at e byt e
0x49 S 0x52 PAGE
0 x6 9   0 x15  er r o r  
messag e
0x49 S 0x4B RN1..6
EM S request s ACK
0x49 0x02 0x06 0x08
EM S request s t o read eeprom 
page
EM S receives ACK
Smart ra3 responds 
wit h a ACK
0x69 0x02 0x06 0x08
EM S request s IDE f rom 
transponder wit h 0x4B 
+ extra byt es
From IDE response EM S 
knows t ype of  Smart ra, and 
TP IDE.