Robert Bosch Pty Ltd VIMA01 Benutzerhandbuch

Seite von 38
  
 
PROTOCOL SPECIFICATION 
F005VP0801 
ROBERT BOSCH 
(AUSTRALIA) PTY. LTD. 
A.B.N. 48 004 315 628
 
SMARTRA III IMMOBILISER 
Page 39 of 49 
 
 
Issue Number: 
1.0 
Dev No.
 3881 
Valid from: 
14/2/06 
Print Date: 
23 March, 2007 
© THIS DRAWING IS THE EXCLUSIVE PROPERTY OF ROBERT  BOSCH (AUSTRALIA)  PTY. LTD.  WITHOUT THEIR CONSENT IT MAY NOT BE REPRODUCED OR GIVEN TO THIRD PARTIES. 
DEV04205.9/I-1 
 
5.21 
Message Flow 20: 
– Old Smartra with a new EMS 
This combination will not allow automobile to start up as the system isn’t setup correctly. 
5.21.1.1  Message Sequence 
Command  
06h 
53h  
4Bh  
41h  
52h  
57h 
4Eh  
54h  
15h 
Sequence 
1 - 
 2 
- - - - 
 - - 
5.21.1.2  Message Flow Detail 
Msg 
Flow 
no. 
T
S
EMS Mode 
description 
Description 
EMS message 
Data EMS message 
Description 
Smartra Response 
Data Smartra Message 
20 
old 
L Old 
Smartra 
with a new 
learnt EMS 
ACK request 
IDE Request 1 
IDE Request 2 
IDE Request 3 
0x49 0x02 0x06 0x08 
0x49 S 0x4B RN1..6  
0x49 S 0x4B RN1..6  
0x49 S 0x4B RN1..6  
ACK response 
IDE Response 1 
IDE Response 2 
IDE Response 3 
0x69 0x02 0x06 0x08 
0x69 S IDE1..4 
0x69 S IDE1..4 
0x69 S IDE1..4 
5.21.2  Message Flow Diagram: 
 
 
 
 
 
 
 
ACK request
IDE request 1
T r ansp o nd er [ l ear nt ]
Ol d   Smar t r a
N ew  EM S[ lear nt ]
EM S requests IDE from 
transponder with 0x4B 
+ extra byt es
EM S knows there is a 
Smart ra2 when it is 
expecting a Smartra3.  Try 
again.
EM S request s ACK
0x49 0x02 0x06 0x08
0x69 0x02 0x06 0x08
0x49 S 0x4B + RN1..6
0x69 S IDE1..4 
Message Flow will stop as the EMS knows that 
there is a Smartra2 in the system when it is 
expecting a configured Smartra3.
IDE request 2
EM S requests IDE from 
transponder with 0x4B 
+ extra byt es
EM S knows there is a 
Smart ra2 when it is 
expecting a Smartra3.  Try 
again.
0x49 S 0x4B + RN1..6
0x69 S IDE1..4 
IDE request 3
EM S  request s  IDE  f rom 
t ransponder wit h 0x4B 
+ ext ra bytes
EM S knows t here is a 
Smartra2 when it  is 
expect ing a Smart ra3.  The 
EM S needs t o raise an error 
as there is a miss-mat ch
0x49 S 0x4B + RN1..6
0x69 S IDE1..4 
EM S receives ACK
Smart ra2 responds 
with a ACK