Hunter Industries Inc RMT Benutzerhandbuch
20
TRoublesHooTinG Guide .............................................................
PROBLEM
CAUSES
SOLUTIONS
Transmitter display is blank.
Transmitter is off.
Batteries are dead.
Press any button for 1 second.
Can’t access all the desired
stations on the Transmitter.
stations on the Transmitter.
Maximum station number is set wrong.
See “Changing the Maximum Station.”
Receiver doesn’t beep 4 times
after plugging it in.
after plugging it in.
SmartPort® is not connected properly.
Controller has no power.
Controller has no power.
Recheck SmartPort wiring.
Check controller power.
Check controller power.
Receiver won’t respond to
Transmitter.
Transmitter.
Receiver and Transmitter address don’t match
Relearn address at receiver.
Transmitter display stays on.
Transmitter will turn off automatically.
Wait approximately 5 minutes without pressing any
buttons. Transmitter will “fall asleep.”
buttons. Transmitter will “fall asleep.”
“ERR” message in controller
display when controller is in the
run position.
display when controller is in the
run position.
SmartPort wiring leads have been extended and are
receiving radio interference.
receiving radio interference.
Replace lengthened wire with shielded cable to
prohibit radio interference. Use Hunter ROAM-SCWH.
See “Extending Wiring on SmartPort Harness.”
prohibit radio interference. Use Hunter ROAM-SCWH.
See “Extending Wiring on SmartPort Harness.”
Receiver does not receive signal
from remote held at close range.
from remote held at close range.
Mismatch of addresses in transmitter and receiver.
Reset address of receiver.
Remote has short range
(i.e. less than 100 feet).
(i.e. less than 100 feet).
Check for interference causes.
See “Maximizing Operating Range.”
LIT-477.a.indd 20