115    
 
com.wiegand.<n>.physical.tpw 
This variable is used to set or to interrogate the pulse width time (Tpw), 
where the pulse width time is specified in microseconds. Values of 40 to 
250 µs are valid. The default value is 50 µs. The variable will return a value 
in the range 40 to 250 µs.  n = 1 to 4. 
Note that the WIM has a granularity of 5 µs and pulse_width_times will be 
truncated to the nearest 5 µs. 
Also note that these are nominal time values for 470Ω pull-up loads on the 
Wiegand outputs. The pulse width time lengthens for higher values of pull-
ups, and shortens for lower values. This phenomenon is caused by Miller 
capacitance on the loads. The 5 µs granularity on the pulse_width_time can 
be used to tailor the pulse width to the required value. 
Type
Type
Type
Type    
var 
Permissions
Permissions
Permissions
Permissions    
guest=r,admin=rw 
Data Type
Data Type
Data Type
Data Type    
int 
Default
Default
Default
Default    
50 
Min
Min
Min
Min    
40 
Max
Max
Max
Max    
255 
 
error.wiegand.failure 
This response indicates WIM function failed. 
event.wim.report 
This event is generated each time data is sent to the WIM interface. The 
event returns the translated ID,  timestamp, and antenna value 
Type
Type
Type
Type    
event 
Permissions
Permissions
Permissions
Permissions    
guest=rw,admin=rw 
Return Values
Return Values
Return Values
Return Values    
id (int)  
time (string)  
text (string)