3.2.1.
 
Connecting the Serial Port
Connecting the Serial Port
Connecting the Serial Port
Connecting the Serial Port    
The 6204 RS-232 serial port provides communication up to 115200 Baud. 
This port is accessed through the bulkhead connector on the reader. If you 
are using the serial port for reader communication, connect a serial cable 
from the COM port on your PC to the serial port on the reader. See Figure 2 
for location of the connector.  
Refer to the Chapter 8 – Specifications for details on the bulkhead 
connector. 
3.2.2.
 
Connecting and Configuring the Ethernet Port
Connecting and Configuring the Ethernet Port
Connecting and Configuring the Ethernet Port
Connecting and Configuring the Ethernet Port    
The 6204 Ethernet port is accessed through the bulkhead connector. If you 
are communicating with your reader across a Local Area Network (LAN), 
connect an Ethernet cable from your hub or router to the bulkhead 
connector. 
By default, the reader is configured to use a DHCP server to obtain its IP 
address and related information.  In the event a DHCP server is unavailable, 
the reader will boot with an IP address in the 169.254.x.x subnet.  
In the absence of other readers on the same network, and if no other 
network traffic is observed which references 169.254.1.1, the reader will 
select that address; otherwise, it will select a random address on the 
169.254.x.x subnet. 
IP address settings can be changed using RST. Refer to the View or Change 
the Reader’s Network Settings
 section in Chapter 5. 
Refer to the Chapter 8 – Specifications for details on the bulkhead 
connector. 
3.2.3.
 
Connecting Digital Inputs/Outputs
Connecting Digital Inputs/Outputs
Connecting Digital Inputs/Outputs
Connecting Digital Inputs/Outputs    
The 6204 is equipped with a general purpose digital input/output (I/O) port 
that provides four optically isolated 5-24 VDC input signals and four open-
collector output signals. The digital inputs can be used as general purpose 
inputs or to trigger the reader for tag reading. These inputs can be 
configured to provide an external read trigger from proximity sensors, photo 
switches, or other devices. 
The digital outputs can be used as general purpose outputs, to indicate tag 
reading activity, or to indicate the reader is transmitting (RF On). The 
outputs can also be configured to trigger conveyor gates or other access 
control and sorting devices. For detailed information on configuring the 
digital inputs and outputs refer to Chapter 7.