8.5.
 
Digi
Digi
Digi
Digital Input Alarm Generation
tal Input Alarm Generation
tal Input Alarm Generation
tal Input Alarm Generation    
The 6204 can be configured to generate an alarm when a digital input is 
disconnected or sensor failure is detected. The alarm is triggered when the 
signal level on the digital input stays in the specified state longer than the 
specified alarm timeout.  This behavior can be configured independently for 
each digital input. 
The configuration variable 
dio.in.alarm.logic_leve
l
.<N>
 (where <N> is 
1,2,3,4) sets whether the alarm is coupled to a input logic level of 0 (low) or 
1 (high). 
The configuration variable 
dio.in.alarm.timeout.<N>
 (where <N> is 1,2,3,4) 
sets the amount of time, in seconds, to wait for a signal state change. A 
value of 0 (default) disables alarm generation. 
The digital input logic level is used along with the corresponding digital input 
pin timeout value to determine if an alarm (in the form of an event) should 
be generated. If a timeout value is set, the input pin is monitored. If the 
input pin value does not change during the timeout period AND the input 
pin value matches the alarm logic level, the event 
event.dio.in.alarm.timeout.n
 (where n is the pin number) is generated. This 
alarm event generation can be helpful in alerting to the loss of digital inputs 
to the reader.