Product Technical Specification 
Detailed Interface Specifications 
Refer to the following table for the electrical characteristics of the JTAG interface. 
Table 29. 
JTAG Electrical Characteristics 
Symbol 
Parameter 
Minimum 
Typical 
Maximum 
Unit 
F
tck
 
JTAG_TCK clock period 
0.038 (TBC) 
26 (TBC) 
78 (TBC) 
MHz  
t
c2
 
JTAG_TCK clock period high 
12 (TBC) 
ns 
t
c3
 
JTAG_TCK clock period low 
12 (TBC) 
ns 
t
c4
 
JTAG_TDI setup time to JTAG_TCK 
12 (TBC) 
ns 
t
c5
 
JTAG_TDI hold time from JTAG_TCK 
10 (TBC) 
ns 
t
c6
 
JTAG_TDO valid before JTAG_TCK 
low-end 
0 (TBC) 
t
c7
 
JTAG_TDO valid after JTAG_TCK 
high begin 
20 (TBC) 
ns 
 
 
Figure 7. 
JTAG Timing Waveform 
3.15.  Wake Up Signal (WAKE-UP) 
The AirPrime HL77xx modules provide one WAKE-UP signal. 
The WAKE-UP signal is used to wake the system up from ultra-low power modes (from OFF or Sleep 
modes, FAST_SHUTDOWN, or after a software power off). This signal should be set to high level 
(external 1.8V) for at least (TBD) ms until the system is active to wake the module up from these 
modes. 
The system will not be allowed to go into ultra-low or off mode for as long as this signal is kept high. 
By default, the software waits for a high state to wake-up. 
Note:  
The module has an embedded pull-down on this signal. After a power off mode, the only way to 
restart the module is to perform a hardware power off then power on if this signal is not used. 
Refer to the following table for the pad description of the WAKE-UP interface. 
Table 30. 
WAKE-UP Pad Description 
Pad Number 
Signal Name 
I/O 
I/O Type 
Description 
19 
WAKE-UP 
1.8V 
WAKE-UP