Sierra Wireless HL7748 Benutzerhandbuch

Seite von 53
 
41110555 
Rev 1.0 
September 21, 2017 
44 
6.  Reliability Specification (TBC) 
AirPrime HL77xx modules will be tested against the Sierra Wireless Industrial Reliability Specification 
defined below. 
6.1. 
Reliability Compliance 
AirPrime HL77xx modules connected on a development kit board application are targeted to be 
compliant with the following requirements. 
Table 38. 
Standards Conformity 
Abbreviation 
Definition 
IEC 
International Electro technical Commission  
ISO  
International Organization for Standardization 
6.2. 
Reliability Prediction Model 
6.2.1. 
Life Stress Test 
The following tests the AirPrime HL77xx modules’ product performance. 
Table 39. 
Life Stress Test 
Designation 
Condition 
Performance Test 
PT3T & PTRT 
 
Standard: N/A 
Special conditions: 
 
Temperature: 
 
Class A: -30°C to +70°C 
 
Class B: -40°C to +85°C 
 
Rate of temperature change: ± 3°C/min 
 
Recovery time: 3 hours 
Operating conditions: Powered 
Duration: 14 days