Product Technical Specification
Reliability Specification (TBC)
6.2.6.
Handling Resistance Stress Tests
The following tests the AirPrime HL77xx modules’ resistance to handling malfunctions and damage.
Table 44.
Handling Resistance Stress Tests
Designation
Condition
ESDC Test
Standard: JESD22-A114, JESD22-A115, JESD22-C101
Special conditions:
•
HBM (Human Body Model): 1KV (Class 1C)
•
MM (Machine Model): 200V
•
CDM (Charged Device Model): 250V (Class II)
Operating conditions: Powered
Duration: 3 days
ESD Test
Standard: IEC 61000-4-2
Special conditions:
•
Contact Voltage: ±2kV, ±4kV, ±6kV
•
Air Voltage: ±2kV, ±4kV, ±8kV
Operating conditions: Powered
Duration: 3 days
Free Fall Test
FFT 1
FFT 1
Standard: IEC 60068-2-32, Test Ed
Special conditions:
•
Number of drops: 2 drops per unit
•
Height: 1m
Operating conditions: Un-powered