ET-905WS INSTRUCTION MANUAL
 
Congratulations on your purchase of the new Williams-Sonoma Wireless BBQ Thermometer. This 
unit will allow you to see the temperature of your food cooking in the oven or on the grill from 
anywhere in your home. The unit beeps you when your food is ready. The following instructions will 
show you how to easily use the thermometer.
Components 
1.  1– Receiver unit 
2.  1– Transmitter unit
3.  1– Detachable stainless steel FOOD probe 
4.  1–AAA batteries (4 included) 
Receiver Features
●  LCD (Liquid Crystal Display) – Displays all icons, temperature and time.
●  BATTERY COMPARTMENT – Holds 2 AAA batteries.
Buttons
1.  /HR – In THERMOMETER MODE, press to increase the set temperature. Press once to increase
1 degree. In TIMER MODE, when the TIMER is stopped, press to set the hour. Press once to
increase 1 hour.   In both modes press and hold to increase 10 digits per second.   
2.  ▼/MIN – In THERMOMETER MODE, press to decrease the set temperature. Press once to
decrease 1 degree. In TIMER MODE, when the TIMER is stopped, press to set the minute. Press
once to decrease 1 minute. In both modes press and hold to increase 10 digits per second. 
3.  MEAT/  – In any mode, press once to turn on the backlight for 10 seconds. In the thermometer
mode, when the Backlight is on, press once to select the meat type: Beef   Veal   Lamb   
Pork   Chicken   Turkey   Hamburg   Beef…
4.  CLEAR/ºC/ºF – In thermometer mode, press once to select the temperature units of measure
either ºF or ºC. In the timer mode, press once to clear time setting when the timer is not
counting In the thermometer mode or Timer mode, press and hold for 2 seconds to enter the
RF register mode. The unit will flash“---“.Press again to exit this RF register mode.
5.  TASTE – In the thermometer mode, press once to select the taste level of the current meat.
The taste level may vary according to different meat selected. The corresponding default 
temperature setting will display.
6.  MODE/  – When the unit is on, press once to select the thermometer mode or the timer mode.
Press and hold for 2 seconds to turn the receiver unit ON or OFF.
7.  START/STOP – In timer mode, when the time display is 0:00, press once the timer will start to
count up, and the icon “   ”will blink. If the Timer isn’t 0:00, press once to activate the timer to
count down, and the icon “   ”will blink. In the timer mode, when the timer is counting, press
once the timer will stop counting temporally. If press again, the timer will continue to count.
Transmitter Features   
Components:
1.  1– BATTERY COMPARTMENT – holds 2 AAA batteries.
2.  1– Stainless steel FOOD probe. 
3.  1– LED Light.
Buttons 
1.  Re-sync 
– Transmit manually, terminates the auto registration process. Press and hold for 2
seconds to register the Registration Code with the receiver through radio frequency.
2.  Power 
– Press and hold for 2 seconds to turn the transmitter ON/OFF.
3.  The LED will flicker twice when the unit is turned on or when the Re-sync button is pressed and
held for 2 seconds.
Installing the batteries:
Open the battery compartment of the receiver and insert two “AAA” batteries with correct
polarity. And then open the battery compartment of the transmitter and insert two “AAA”
batteries with correct polarity.
Registering Receiver & Transmitter:
1.  WHEN USED AS A THERMOMETER: First you must register the base unit with the remote unit (the
remote unit has the display showing the food selections). To register the unit, please do the
following:
 ●  Turn the unit on by holding the MODE button for 2 seconds on the receiver unit until you
hear the BEEP sound.
 ●  Plug in the stainless steel probe into the transmitter unit and turn on the transmitter unit by
pressing and holding the 
button for 2 seconds as the LED will flicker twice. This must be
done within 120 seconds of turning the unit on.
 ●  When the transmitter turned on, the probe temperature will display on receiver after
plugging in the probe. While the temperature appears on the LCD the unit will beep once.
 ●  If this does not happen repeat the above procedures.
NOTE: THE PROBE MUST BE PLUGGED INTO THE TRANSMITTER FOR THE UNIT TO WORK.
2.  ONCE THE UNIT IS ON: Press the MODE button again to change the unit from the thermometer
function to the timer function. This button will change the feature of timer/thermometer back
and forth.
Loss link alert:
HOW TO KNOW IF THE SIGNAL IS LOST: The receiver unit will normally work within 150 feet of the
transmitter. If the receiver is taken out of range or there is abnormal external interference the
receiver may not be able to receive the transmission from the transmitter. Four minutes after this 
happens the unit will alert you by beeping once for every 4 seconds, meanwhile, the“---“will flash
on the display to tell you to re-sync the signal. If this happens you need to move the unit close to 
the transmitter and follow the following instructions.
To regain transmission signal, the following measures can be taken.
1.  Move the receiver close to the transmitter to see if the receiver can regain signal. If this
doesn’t work, the following two procedures can be followed.
2. 
 ●  Hold the CLEAR button for 2 seconds until the probe temperature dashed lines start to blink
---. 
 ●  Press and hold the RESYNC button
of the transmitter and the LED will flicker for a few
seconds. This has to be done within 120 seconds of turning the unit on.
 ●  If the receiver is registered successfully; the receiver will beep once and show the probe
temperature. If registration is not succeeded, after 12 seconds, repeat the above process
again.
3.  Turn OFF the Receiver and then turn back ON with the --- showing on the LCD. Press and hold
the RESYNC button
 of the transmitter 2 seconds within 120 seconds and the temperatures 
should appear on the receiver display.