Expansion Hub Front Panel
4-6
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev D
Green / Green
Green / Green 
(60-ppm)
• Optical power received is above minimum (the Main Hub is con-
nected) although the cable optical loss may be greater than recom-
mended maximum.
• Optical power transmitted (uplink laser) is normal and communica-
tions with the Main Hub are normal.
• The Expansion Hub is reporting a commanded lockout.
Green / Red
Red / Green
• A fault condition was detected, optical power received is below mini-
mum. 
(the Main Hub is not connected, is not powered, or the Main Hub’s 
downlink laser has failed, or the downlink fiber is disconnected or 
damaged.)
Green / Green
Red / Red
• The Expansion Hub is reporting a fault condition.
• Optical power received is above minimum (Main Hub is connected) 
although the cable optical loss may be greater than recommended 
maximum.
• Optical power transmitted is below minimum (Expansion Hub uplink 
laser has failed; unable to communicate with Main Hub). 
UL STATUS
 
LED state must be checked within the first 90 seconds after power on. 
If initially green, then red after 90 seconds, it means that there is no 
communication with the Main Hub. If red on power up, replace the 
Expansion Hub.
Green / Red
Red / Red
• Optical power received is below minimum (the Main Hub is not con-
nected, is not powered, or the Main Hub’s downlink laser has failed, 
or the downlink fiber is disconnected or damaged.)
• Optical power transmitted is below minimum (the Expansion Hub 
uplink laser has failed; is unable to communicate with the Main Hub). 
UL STATUS
 LED state must be checked within the first 90 seconds 
after power on. If initially green, then red after 90 seconds, it means 
that there is no communication with the Main Hub. If red on power 
up, the uplink laser has failed, replace the Expansion Hub.
Green /Off
Green / Off
• Expansion Hub is in factory test mode, return it to the factory.
Red/ Don’t 
Care
Red/ Don’t 
Care
• One or more power supplies are out of specification. The hub needs to 
be replaced.
Green/ Red
Off/ Off
• Expansion Hub failure. The Hub must be replaced.
Table 4-1
Expansion Hub Unit Status and DL/UL Status LED States  (continued)
LED State
Indicates
POWER
EH STATUS
DL STATUS
UL STATUS
POWER
EH STATUS
DL STATUS
UL STATUS
POWER
EH STATUS
DL STATUS
UL STATUS
POWER
EH STATUS
DL STATUS
UL STATUS
POWER
EH STATUS
DL STATUS
UL STATUS
POWER
EH STATUS
DL STATUS
UL STATUS
POWER
EH STATUS
DL STATUS
UL STATUS