Adtran TRC4206 Benutzerhandbuch

Seite von 66
Section 5, User Interface Guide
TRACER 4206 System Manual
50
© 2002 ADTRAN, Inc.
612804206L1-1A
>T1A S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > T1A I
NTERFACE
 A
LARMS
Displays any active alarms on the T1A link (reported from both the local and remote TRACER 4206 
units). These alarms include Red, Blue, Yellow, AIS, and bipolar violations (
BPV
). See Section 6, 
Troubleshooting Guide, for more information on these alarms.
>T1A S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > T1A L
INE
 B
UILD
 O
UT
Configures the T1A for the appropriate line buildout, based on the distance to the T1A equipment. 
>T1A S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > A
LARM
 R
EPORTING
Determines whether the TRACER 4206 unit will report active alarms. If 
D
ISABLED
, no alarms will be 
displayed on this menu page. The 
A
LARM
 R
EPORTING
 parameter is independently configured for the local 
and remote TRACER 4206 units. When 
D
ISABLED
, the front panel LED alarms will also be disabled (OFF).
>T1A S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > S
IGNALING
Configures the framing format for the T1A link for both the local and remote TRACER 4206 units. The 
TRACER 4206 transports T1A data across the link (as long as the T1A signal is properly timed). 
Configure the framing format (using the 
S
IGNALING
 menu) to enable the TRACER 4206 to monitor 
incoming framing error events and indicate problems with the attached metallic service. The TRACER 
4206 supports both 
ESF
 and 
D4
 framing formats.
>T1A S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > L
INE
 C
ODE
Sets the line coding for the T1A link. The TRACER 4206 supports 
B8ZS 
and
 AMI
 line coding.
>T1A S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > L
OOP
/N
ORMAL
 S
TATE
Controls the loop status of the T1A link. Activates/deactivates loopback conditions for testing purposes.
>T1A S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > L
OOP
/N
ORMAL
 S
TATE
 > N
ORMAL
The T1A link is in normal data transport mode - there are no active loopbacks.
Table 1.  T1 Interface Alarms
RED
Activates when a local facility failure occurs.
BPV
Activates when the incoming T1 stream presents bipolar violations (BPVs).
AIS
Activates when an incoming remote alarm is received from a connected T1 device. An AIS 
signal is an unframed All One signal that replaces the normal traffic signal
YEL
Activates when an incoming remote alarm is received from the T1 device indicating that a 
failure has occurred in the received direction.
LOS
Activates when no T1 signal is present from the connected T1 equipment. LOS is 
activated after receiving 192 consecutive zeros.