Robotron Pty Ltd G9P Benutzerhandbuch

Seite von 128
            WiNRADiO G39DDC User’s Guide
 
 
 
119 
your monitor with a ‘quieter’ one, or you can try to relocate your antenna 
further away from your computer.  
While the WiNRADiO Excelsior receiver has been designed to minimize 
interference-related problems, switched-mode computer power supplies 
sometimes still present a challenge. This type of interference would usually 
enter the receiver as common-mode noise, which means that the noise is in 
the same phase on both the active and shielding conductors of the antenna 
lead.  
A good remedy to try is to wind five to ten turns of the antenna lead-in cable 
through a large ferrite core (the doughnut shaped toroid type), near the PC 
end of the cable. This suppresses the common-mode interference, which is 
a typical but curable problem with PC-controlled receivers.  
A most effective remedy is the WiNRADiO WR-CMC-30 Common-Mode 
Choke
 (see www.winradio.com/cmc30), which is well proven to cure most 
common-mode interference problems. In extreme cases, two or more chokes 
can be used, placed strategically along the antenna lead where suitable 
grounding points exist. 
Long wire antennas, while most commonly used, also appear to be most 
susceptible to problems related to ground loops. If you encounter such 
problems, we would also suggest experimenting with magnetic loop antennas 
which do not require grounding at all.  
Another type of interference which you may encounter is intermodulation 
interference
. This is usually caused by strong local stations, whose 
frequencies combine to create ‘ghost’ signals on frequencies which are 
arithmetic combinations of the stations’ frequencies. These ‘ghost’ signals can 
sometimes coincide with useful frequencies, rendering them partially or 
completely unusable. They will usually disappear when you enable the 
Attenuator. In some cases, intermodulation interference in the shortwave 
band is caused by a strong local MW station and the most effective remedy 
would be to install an external MW filter