Installation Guide
4
Installation in the heater
NOTE: First, disconnect the heater wires from the supply wires. If the heater has a built-in
thermostat, remove it.
ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect AC power
before beginning installation
.
Wiring must comply with local electrical codes. Use special CO/ALR solderless
connectors if supply wires are made of aluminum.
1)
Remove the knockout on the side of the 
heater.
2)
Remove the locknut from the antenna and 
peel off the adhesive backing. Feed the 
antenna wires through the knockout and 
install the antenna vertically as shown. 
Put the locknut and tighten.
3)
Peel off the adhesive backing of the relay 
and stick the relay on the back panel 
inside the wiring compartment with the 
relay wires directed upwards. 
4)
Connect the heater wires and the supply 
wires to the relay wires as shown.
5)
Insert the antenna plug into the relay 
receptacle until you hear a click.
6)
Put the heater cover back. (If a built-in 
thermostat was removed, install one of 
the supplied plugs to cover the hole on the 
existing cover.) Apply power to the heater. 
Do not install the antenna cover yet.
L2    L1 :  For 240V application
N    L    :  For 120V application
BlueB
lu
e
BlackB
la
ck
RedR
e
d
Install plug if 
applicable.
69-2474EFS (Honeywell YTL9160 System Installation Guide).book  Page 4  Friday, April 29, 2011  12:04 PM