Murata Electronics North America 2410P Benutzerhandbuch

Seite von 59
WIT2410P 
© 2000- 2008 Cirronet™ Inc 
19 
M-2410P-0000 Rev G2 
4.  MODEM INTERFACE 
 
Electrical connection to the WIT2410 is made 
through a 16-pin male header on the modem 
module.  The signals are 3.3 volt signals and form 
an RS-232 style asynchronous serial interface.   
 
The table below provides the connector pinout. 
 
Pin 
Signal 
Type 
Description 
GND 
Signal and chassis ground 
TXD 
Input 
Transmit data.  Input for serial data to be transmitted.  In Control Mode 
also used to transmit modem commands to the modem. 
RXD 
Output 
Receive data.  Output for received serial data.  In Control Mode, also 
carries receive modem status from the modem. 
 
Input 
Configuration selector.  Used to switch between Control and Data Modes.  
Normally, CFG will be set for Data Mode.  An internal 10K pull-up enables 
Data Mode if this signal is left unconnected.  Control Mode is also 
accessible by transmitting an escape sequence immediately after wake 
up or power up. 
 
(0v) 
1 = Control Mode 
 
(3.3v) 
0 = Data Mode 
 
Input 
Request to send.  Gates the flow of receive data from the radio to the user 
on or off.  In normal operation this signal should be asserted.  When 
negated, the WIT2410 buffers receive data until RTS is asserted. 
 
(0v) 
1 = Receive data (RxD) enabled 
 
(3.3v) 
0 = Receive data (RxD) disabled. 
SLEEP 
Input 
Sleeps/wakes radio transceiver.  In sleep mode all radio functions are 
disabled consuming less than 50µA.  At wake up, any user programmed 
configuration settings are refreshed from non-volatile memory, clearing 
any temporary settings that may have been set. 
 
(3.3v) 
1 = Sleep Radio 
 
(0v) 
0 = Wake Radio  
 
Output 
Data carrier detect.  For remotes, indicates the remote has successfully 
acquired the hopping pattern of the base station. 
 
(0v) 
1 = Carrier detected (synchronized) 
 
(3.3v) 
0 = No carrier detected (not synchronized) 
 
Output 
Clear to send.  Used to control transmit flow from the user to the radio. 
 
(0v) 
1 = Transmit buffer not full, continue transmitting 
 
(3.3v) 
0 = Transmit buffer full, stop transmitting 
 9 
Reserved for future use. Do not connect. 
10 
 
Input 
Resets the radio. 
11-15 
Reserved for future use. Do not connect. 
16 
VCC 
Positive supply.  Min 3.3 v, 5.0 v nominal, 10.0 v max. 
RTS 
DCD 
CTS 
CFG 
Reset