7.4.3 Bank 0x02 - Status Parameters
Bank
Location
Name
R/W
Size
Range
Default
0x02
0x00
MacAddress
R
0x03
0..0xFFFFFF
Fixed value
0x02
0x03
CurrNwkID
R
0x01
0..63, 255
Current Value
0x02
0x04
CurrFreqBand
R
0x01
0..2, 255
Current Value
0x02
0x05
LinkStatus
R
0x01
0..6
Current status
0x02
0x06
RemoteSlotSize
R
0x01
0..109
Current Value
0x02
0x07
SlotNumber
R
0x01
0..7
Current Value
0x02
0x08
HardwareVersion
R
0x01
0x41..0x5A
0x43 = Rev “C”
0x02
0x09
FirmwareVersion
R
0x01
0x00..0xFF
Current FW load
0x02
0x0A
FirmwareBuildNum
R
0x02
0..65535
Current FW load
0x02
0x0C
FirmwareBuildDate
R
0x03
BCD (“YYMMDD”)
Current FW load
0x02
0x0F
FirmwareBuildTime
R
0x03
BCD (“HHMMSS”)
Current FW load
0x02
0x12
RssiIdle
R
0x01
-128..127
Current Value
0x02
0x13
RssiLast
R
0x01
-128..127
Current Value
0x02
0x14
AvgBeaconPower
R
0x01
-128..127
Current Value
0x02
0x15
ParentMacAddress
R
0x03
0..0xFFFFFF
Current Value
0x02
0x18
ModelNumber
R
0x01
0x24, 0x90
0x24 = DNT24
0x02
0x19
TxQueue
R
0x01
0..1
Current Value
Table 7.4.3.1
MacAddress - this parameter holds the radio's unique 24-bit MAC address.
CurrNwkID - this parameter holds the ID of the network the radio is currently assigned to or connected to.
A value of 255 (0xFF) means the radio has powered up and is scanning for a network but has not yet
joined one.
CurrFreqBand - this parameter holds the frequency band of the network that the radio is currently
assigned to or connected to. A value of 0xFF means the radio has powered up and is scanning for a
network but has not yet joined one.
LinkStatus - this parameter holds the link status of a router or remote:
0x00  =  idle
0x01  =  lost link
0x02  =  acquiring link
0x03  =  collecting parameters from the base
0x04  =  registering
0x05  =  registered
0x06  =  linked in fast beacon mode
RemoteSlotSize - this parameter holds the current remote slot size, defined as the maximum number of
message bytes a remote can send on a single hop.  The RemoteSlotSize is calculated by each radio in a
system based on the values of the HopDuration, BaseSlotSize, and NumSlots parameters.
SlotNumber - this parameter holds the current slot number assigned to a router or remote.
HarwareVersion - this parameter holds an identifier indicating the hardware revision (ASCII character). A
value of 0x43 is defined for the DNT24 Revision hardware.
FirmwareVersion - this parameter holds the firmware version of the radio in 2-digit BCD format.