Proxim Wireless Corporation US5358-GX1 Benutzerhandbuch

Seite von 117
Lynx.GX and Tsunami Wireless Radio Installation and Maintenance 
 
IDU Controls 
Far End Pushbutton 
Yes 
 
Front Panel LEDs 
IDU 
Green = Indoor Unit OK 
Yellow = Warning condition in IDU (over-temp or both fans failed) 
Red = All fans failed, over-temp (> 55°C), or NMU/IDU communication failure 
Cable 
Green = ODU Cable OK 
Red = ODU Cable shorted 
ODU 
Green = Outdoor Unit OK 
Red = Over-temp (>65°C), IDU to ODU communication failure, DC power loss, 
or Outdoor Unit detected hardware failure 
Yellow = Over temperature alarm, exceeds 60°C 
RF Link 
Green = Link established with BER <10E-6 
Yellow = BER ≥ 10E-6; any bit errors due to FEC overload 
Red = BER > 10E-3 or Loss of Sync 
Blinking Red = Link ID does not match with far end ratio 
Loopback 
Flashing Yellow = Loopback service is enabled 
Solid Yellow = Internal signal generator turned on and errors detected online 
NMS 
(10/100 
Base-T) 
Green = Tx or Rx data present on the NMS interface (handshaking is occurring) 
Off = No NMS data, interface connection detected 
 
NMS Connector LEDs 
10/100 Base-Tx NMS 
Link:  Green = Link On;  Off = Link Off 
Duplex:  Green = Full/Auto;  Off = Half Duplex 
100 Base-Tx 
Link:  Green = Link On;  Off = Link Off 
Duplex:  Green = Full/Auto;  Off = Half Duplex 
 
Appendix C.  Technical Specifications 
C-101 
CPN 62140 
12/01/02