Zebra Technologies Corporation RFID-R110XI-03 Benutzerhandbuch

Seite von 184
78
R110Xi/R170Xi User Guide
12/17/04
23063L-003 Rev. 2
RFID Guidelines
^HR
^HR
Calibrate RFID Transponder Position
Description  This command initiates an RFID transponder calibration for a specific RFID 
label and returns the results to the host computer. This calibration is used to determine the 
optimal programming position for RFID media that may not meet the transponder placement 
specifications for the printer.
During transponder calibration, the printer feeds the RFID label one-dot row at a time while 
taking readings (via the READ TAG command and the WRITE TAG commands) to profile the 
RFID transponder. Based on the results, the printer determines the optimal programming 
position for the label and returns a results table to the host. The calibrated value is used as the 
programming position for the 
^RS
 command, can be overwritten by the 
^RS
 command, and is 
saved to nonvolatile memory (the value is saved even if the power is turned off).
This calibration takes into account the print mode, backfeed mode, and tear off position. The 
RUN
 option in the 
RFID TAG CALIB
 front panel parameter performs the same calibration 
but does not create a results table.
Format  
^HRa,b
The following table identifies the parameters for this format.
Comments  
Based on the recommended transponder placement position for most RFID labels, the 
printer’s default RFID programming position is the label length minus 1 mm (1/16 in.). 
To return to the default programming position at any time, use the RESTORE option in the 
RFID TAG CALIB
Note • 
You do not need to perform transponder calibration for RFID media that meets the 
transponder placement specifications for the printer. To order media that is designed for use 
with your RFID printer, contact your authorized Zebra reseller.
If a label format specifies a value for parameter 
p
 (read/write position of the transponder) in 
the 
^RS
 command, that value will be used for the programming position for all RFID labels 
until a new position is specified or until the printer is turned Off (
O
) and then back On (
I
).
Parameters
Details
a
=  start string
User text to appear before the results table.
Accepted values: any string less than 65 characters
Default value: 
start
b
= end string
User text to appear after the results table.
Accepted values: any string less than 65 characters
Default value: 
end