R4Mplus User Guide
Routine Care and Adjustments
Cleaning Procedures
Clean the Peel-Off Assembly
The Peel-Off option is required.
Refer to 
 and perform the following procedure if adhesive 
buildup begins to affect peel-off performance.
1. Open the printhead assembly.
2. Close the peel assembly to prevent bending the tear-off/peel-off bar during cleaning. 
3. Use the Preventive Maintenance Kit (Zebra part number 47362) or a solution of 
90% Isopropyl alcohol and 10% deionized water and swab to remove excess adhesive 
from the tear-off/peel-off bar. Allow the solvent to evaporate.
4. Open the peel assembly by pivoting the module toward you.
5. Manually rotate the pinch roller and clean thoroughly with solvent and a swab.
6. Close the peel assembly.
7. Close the printhead assembly.
Caution • Ensure that the printhead is fully open and engaged in the up 
position. If the printhead is not latched in the up position, it could fall on your 
hand during the procedure.
Note • Apply minimum force when cleaning the tear-off/peel-off bar. Excessive 
force can cause the tear-off/peel-off bar to bend, which could have a negative 
effect on peel performance.
Note • When cleaning the tear-off/peel-off bar or the pinch roller, remove 
excess solvent with a pad to ensure the solvent has dried before printing.