Powerwave Technologies Inc. MCPS2135 Benutzerhandbuch
MCPS2135 InstallationPlanning and Preparation
Introduction
MCPS2135 System Operation
17
2001 Spectrian Corporation. All rights reserved.
4. Unpack the MCPS2135 shelf and record its serial number. Ensure the
shelf is in the proper upright vertical orientation and slide it onto the
mounting rails.
mounting rails.
5. Use the supplied mounting screws to attach the shelf to the rack. Tighten
rack mounting screws securely.
3.3.2 Install Modules in Shelf
1. Unpack each RF module. Align each module with the guides in an
amplifier slot and slide the module as far as possible into the shelf,
making sure the module is fully seated. Note that each module weighs
approximately 50 lbs (22.7 kg); get a helper to assist if necessary.
Tighten the fasteners at the bottom of each faceplate to lock the modules
in place.
making sure the module is fully seated. Note that each module weighs
approximately 50 lbs (22.7 kg); get a helper to assist if necessary.
Tighten the fasteners at the bottom of each faceplate to lock the modules
in place.
2. Unpack and install the Amplifier Management Module (AMM) module
in the rightmost slot of the shelf. Tighten the fastener at the bottom of the
faceplate to lock the module in place.
faceplate to lock the module in place.
3. Inspect the alignment of the finished installation, and adjust if needed. If
no problems are found, rack installation is complete.
3.4 Cable and Wire Connections
3.4.1 Connect Chassis Ground Wire
1. Locate the chassis ground stud on the rear of the MCPS2135 for ground
wire attachment.
2. Measure the distance and routing between the MCPS2135 ground stud
and an attachment point to earth ground. Cut a length of #8 AWG
insulated (green) solid copper wire sufficient for the connection.
insulated (green) solid copper wire sufficient for the connection.
3. Crimp a ¼” circular lug to one end of the ground wire.
4. Remove the nut and lock washer on the MCPS2135 ground stud. Attach
the DC ground wire lug to the grounding stud on the MCPS2135, and
replace the lock washer and nut. Tighten the nut securely.
replace the lock washer and nut. Tighten the nut securely.
5. Connect the other end of the ground wire to the appropriate earth ground.
6. Use a DVM to verify that the resistance between the chassis ground and
true earth ground is less t han 100 Ohms.
7. Inspect the finished connection. If no problems are discovered, ground
wire installation is complete.
3.4.2 Connect DC Input Power Cables
The MCPS2135 power connection can be made using a pair of wires for each RF
module, or via a single bussed connection. The DC input voltage cabling must be
terminated by crimped lugs and sized to the correct wire gauge to accommodate
the wire length and the DC current requirements of the MCPS2135 in accordance
module, or via a single bussed connection. The DC input voltage cabling must be
terminated by crimped lugs and sized to the correct wire gauge to accommodate
the wire length and the DC current requirements of the MCPS2135 in accordance