4 System Start-Up 
4.1  Introduction 
This section contains instructions on powering up the MCPS2135 amplifier 
system.  These procedures should be followed after installing the MCPS2135 
amplifier system in the rack. 
1.24.2 
Safety Information and Tools 
To avoid injury, installers, technicians, and maintenance personnel must follow 
Spectrian's recommended procedures and observe safety precautions. 
Warning:  The MCPS2135 should only be operated by trained and qualified 
personnel.  Always follow safety warnings. 
Warning:  Persons with cardiac pacemakers should avoid exposure to RF 
radiating elements.  Exposing the human eye to high levels of radio-frequency 
radiation ma y result in the formation of cataracts.  Do not operate exposed 
circuitry or radiating elements with personnel in close proximity to the radiating 
source.  Always replace covers and shields during operation.  
Note:  Before shipment, the MCPS2135 was inspected and found free of 
mechanical and electrical defects.  The electrical performance of the MCPS2135 
should be verified using these procedures.  If there is any deficiency, or if 
electrical performance is not within specifications, notify your Spectrian 
representative immediately. 
Tools  
The following tools are recommended to perform installation tasks. 
• 
HP 436 Power meter 
• 
Digital Volt Meter (DVM) 
 
4.3  Verify system installation 
Before operating the MCPS2135, verify proper installation as described in the 
previous section. 
1.  Verify that there are no obstructions to airflow in the front or rear of the 
MCPS2135. 
2.  Ensure that the DC power supply at the site is functioning normally.  DO 
NOT turn on the DC supply to the MCPS2135 at this time. 
3.  Ensure that the MCPS2135 is physically connected to an input RF signal 
source and terminated in an output load.  Ensure that the RF signal level has 
been set properly.  DO NOT turn on the RF signal source at this time.