Troubleshooting: Receive ATP
68P64115A18–1
Mar 2003
1X SC 4812T Lite BTS Optimization/ATP Software Release R2.16.1.x
DRAFT
6-17
Troubleshooting: Receive ATP
Multi–FER Test Failure
Table 6-17: Troubleshooting Multi-FER Failure
n Step
Action
1
Verify test equipment is configured correctly for a FER test.
2
Verify test equipment is locked to 19.6608 and even second clocks. On the HP 8921 analyzer, the
yellow LED (REF UNLOCK) must be OFF.
yellow LED (REF UNLOCK) must be OFF.
3
Verify MCCs have been loaded with data and are INS_ACT.
4
Disable and re-enable the MCC (1 or more based on extent of failure).
5
Disable, re-load code and data, and re-enable MCC (one or more MCCs based on extent of
failure).
failure).
6
Verify antenna connections to frame are correct based on the LMF directions messages.
7
For diversity RX FER failures in companion frame configurations, verify the following:
7a
– Inter–frame diversity RX cables are correctly connected between RX EXPANSION
connectors on each frame (refer to SC4812ET Lite Installation; 68P09253A36.
7b
– The RX test cable is connected to the correct RX antenna connector on the opposite
companion frame (refer to Table 4-1).
6