Xmark Corporation XLX Benutzerhandbuch

Seite von 4
Large Exciter Instructions
Part Number 805A6201
309 Legget Drive, Ottawa, ON  K2K 3A3, Canada   or 
808 Commerce Park Drive, Ogdensburg, NY  13669 USA
Telephone: 1-613-592-4642  Facsimile:  1-613-592-4296  Web Site: www.xmarksystems.com
© 2002 Instantel Inc. All Rights Reserved. Instantel and Hugs are registered trademarks of 
Instantel Inc. in North America. The hearts logo and Xmark are trademarks of Instantel Inc. Xmark 
is a division of Instantel Inc. Printed in Canada. November 2002. 805U6201 Rev B.
Certifi ed to the ISO 9001 Quality Standard
Materials Required
•   Exciter. Includes door contact, ferrite core (p/n 28A2029-0A2) 
and terminal blocks.
•   Facility  fl oor plan indicating Exciter position and installation 
orientation, and network wiring path.
•   105 Ω network terminator (p/n 805A2401) required to terminate 
network. Two provided with each Controller (p/n 805A2201) or 
Laptop Controller (p/n 805A2202).
•   Suitable mounting hardware, such as wall anchors
•   Optional: Passive infrared sensor for open doorways where door 
contact cannot be used. Refer to Chapter 2 of the Hugs Instal-
lation Manual (p/n 805I0301) for important limitations on 
using PIR sensors.
Specifi cations
Read these instructions thoroughly 
before installing the Exciter. 
Faulty installation can lead to system failure.
!
Installation Considerations
•   Avoid metal—Do not install the Exciter behind or within 2 
inches (50 mm) of metal objects, including metal doors. These 
objects block the detection area of the Exciter.
•   Use door contacts—Door contacts are required to minimize 
nuisance alarms.
•   Confi gure nearby Exciters as slaves—Exciters installed within 
30 feet (9 m) of each other must be confi gured as master and 
slave. Up to four slaves may be connected to one master.
•   Use the supplied ferrite core—Wrap the power cable around the 
supplied ferrite core, as explained in the instructions. Failure to 
do so will void the user’s authority to operate the equipment.
•   Observe temperature and humidity restrictions—Refer to the 
Specifi cations table. 
•   Leave slack in the cable—Leave at least 10 ft. (3 m) of slack in 
the communication and power cable to allow for adjustments in 
the location of the Exciter. 
•   No user adjustments to internal circuitry—Tampering may 
cause component or system failure, or both, and will void the 
warranty.
Important Reference Documents
•   Hugs Installation Manual (p/n 805I0301)
Refer to Chapter 2 of the Hugs Installation Manual for 
detailed information on detection areas, installation options, 
master/slave confi gurations and software settings. 
•   Hugs System Manual (p/n 805U1601)
•   Exciter Tester Sheet (p/n 805U2101)
Materials Required
Specifi cations
Installation Considerations
Important Reference Documents
Have
you:
• Pulled network and 
power cable?
• Resolved power supply 
requirements?
• Selected Exciter orientation 
and position?
If you answered, “No,” to any 
of these questions, refer to 
the Hugs Installation Manual 
before installing.
Frequency
312.5 kHz
Supply
10-30 VDC
Current Draw
200 mA @ 24 VDC, 800 mA maximum
Relay Outputs (2)
30 VDC, 1 A, NO or NC
Detection radius
Adjustable, up to 11 ft.
Communications
LonWorks two-wire
Temperature - operating
32° to 122° F (0° to 50° C)
Temperature - storage
-40° to 176° F (-40° to 80° C)
Humidity
0 - 90% RH @ 70° F (21° C)
Dimensions
Approx 20.7 x 10.9 x 2.3 in. (526 x 275 x 60 mm)
Weight
Approximately 6 lbs. (2.7 kg)