Indyme Solutions Inc TYPEB Benutzerhandbuch

Seite von 5
 
 
 
 
Technical Document 
430710-00 
Rev. H 
Indyme Solutions, Inc. 8295 Aero Place  San Diego, CA 92123 U                              +1.858.268.0717  +1.800.829.6141 
 
Page 1 of 5 
CB982 Wireless Help button 
          Programming and Installation Instructions 
Overview 
The CB982 is a member of the Global Solutions Family. Indyme GSF products operate in the 
800MHz – 900MHz frequency spectrum. The CB982 is a 1-button, GSF Help button designed for 
use at Customer Service  locations. GSF Help buttons are designed to communicate with a GSF 
Access Point. GSF products are not compatible with legacy devices 
 
 
Programming Parameters 
GSF products MUST be properly programmed to establish communication. Programming parameters 
MUST match your configuration. The default settings are for testing purposes only and should not be 
used. Failure to properly program your help button and access point will prevent your devices from 
working. 
  
GSF Help buttons have three primary programming parameters; Netcode, Address and Operating 
Mode. These MUST be programmed in the correct order to establish communication and ensure 
proper operation. Identify the parameters for your configuration before you begin programming.  
 
Using the programming instructions below set the following parameters in order. 
 
  Netcode – unique identification code for the installation environment. 
  Address – alarm number associated with a control unit alarm event. 
  Operating Mode – defines how the help button will respond when activated. 
 
Programming a help button requires a series of button presses. The specific buttons vary by help button type. On 
the CB982, SET is the “PRESS HERE” button and RESET is a small square below the SET button. The assurance LED 
is red and is located above the SET button.
 This LED will flash during programming to indicate your progress. 
 
Netcode 
*00000001 
Address 
*0001 
Operating Mode 
*1 
* Default parameters are for testing purposes only. 
CB982 
RESET 
LED