HID Global Corporation 5553 Benutzerhandbuch
HF Multi ISO RFID Reader User Manual, Firmware V1.4
1508-USM-00-0-04
2.2.4 Protocol Configuration 1 (0Bh)
Default = 41h
The protocol configuration register (PCON) specifies general behavior of the reader device, using
bit flags.
bit flags.
Protocol configuration register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Extended
ID
ID
Extended
Protocol
Protocol
Single-shot LED
New serial
mode
mode
Multitag Protocol Auto-
start
2.2.4.1
Auto start (default 1)
If set, the reader device will start up in continuous read mode automatically.
This is only valid in ASCII mode.
2.2.4.2
Protocol (default 0)
If Protocol is set to ‘1’, then the reader uses binary protocol mode. See
August 2010
Page 25 of 144