Trimble Inc. TRIMTRAC1 Benutzerhandbuch

Seite von 53
 
DRAFT TrimTrac Locator Technical Manual      34 
 
SET_APP_CONFIG  
The SET_APP_CONFIG message is used by the server application to set the 
TrimTrac Application parameters in the TrimTrac locator.  When received the 
TrimTrac locator will send a RESP_APP_CONFIG message in response. 
 
>STKABBBBBBCCCCCCDDDDDDEEEEEEFFFFFFGGGTTHIJK;PW=PPPPPPP
P;ID=YYYYYYYY;*ZZ< 
TrimTrac Configuration Set: 
‘A’ = Application Parameters 
BBBBBB 
Idle Timeout.  Parameter T1.  In seconds (10 – 999999).   
Default 43200 
CCCCCC 
Fix Timeout.  Parameter T2.  In seconds (10 – 999999).  
Default 300   
DDDDDD 
Comm Timeout.  Parameter T3.  In seconds (10 – 999999).  
Default 120 
EEEEEE 
Sleep Time.  Parameter T4.  In seconds (10 – 999999). Default 900 
FFFFFF 
Query Time.  Parameter T5.  In seconds (10 – 999999). Default 60 
GGG 
Almanac Timeout.  Parameter T6.  In hours (10 – 999). Default 168 
TT 
Motion Timeout.  Parameter T7.  In seconds (5 – 99). Default 15 
Motion Report Flag.  0:None; 1:Report first motion before GPS fix. 
Default 0 
Report Delay Flag.  0:Log & Transmit messages; 1:Log messages. 
Default 0 
Diagnostics Mode.  0: None; 1: LED. Default 1 
Communications Mode.  0: SMS; 1: Future.  
Default 0 
PPPPPPPP 
Security Password.  Always 8 digits. Default 00000000 
YYYYYYYY 
Unit ID. Unique unit identifier.  Always 8 digits. Default 00000000 
ZZ 
Checksum.  
Table 14, SET_APP_CONFIG Message